PHASE1 cell in blast chilling
–
18°C Hard Manual SetPoint
-40°C
-60°C
100°C
Ab32
PHASE1 core in blast chilling
–
18°C Hard Manual SetPoint
-18°C
-60°C
100°C
Ab33
PHASE1 time SetPoint in blast
–
18°C Hard Manual full load
80min
0min
240min
Ab34
PHASE2 cell SetPoint in blast
–
18°C Hard Manual
-40°C
-60°C
100°C
Ab35
PHASE2 core SetPoint in blast
–
18°C Hard Manual
-18°C
-60°C
100°C
Ab36
PHASE2 time SetPoint in blast
–
18°C Hard Manual full load
80min
0min
240min
Ab37
PHASE3 cell SetPoint in blast
–
18°C Hard Manual
-40°C
-60°C
100°C
Ab38
PHASE3 core SetPoint in blast
–
18°C Hard Manual
-18°C
-60°C
100°C
Ab39
PHASE3 time SetPoint in blast
–
18°C Hard Manual full load
80min
0min
240min
Ab40
PHASE1 fan speed
5
0
5
Ab41
PHASE2 fan speed
5
0
5
Ab42
PHASE3 fan speed
5
0
5
Ab43
Storage fan speed
5
0
5
Ab44
Blast chilling maximum time Se3°C
120min
0min
999min
Ab45
Blast chilling maximum time SetPoint
–
18°C
300min
0min
999min
Ab46
PHASE1 time SetPoint in blast +3°C Soft Manual half load
30min
0min
240min
Ab47
PHASE2 time SetPoint in blast +3°C Soft Manual half load
30min
0min
240min
Ab48
PHASE3 time SetPoint in blast +3°C Soft Manual half load
30min
0min
240min
Ab49
PHASE1 time SetPoint in blast +3°C Hard Manual half load
30min
0min
240min
Ab50
PHASE2 time SetPoint in blast +3°C Hard Manual half load
30min
0min
240min
Ab51
PHASE3 time SetPoint in blast +3°C Hard Manual half load
30min
0min
240min
Ab52
PHASE1 time SetPoint in blast -18°C Soft Manual half load
80min
0min
240min
Ab53
PHASE2 time SetPoint in blast -18°C Soft Manual half load
80min
0min
240min
Ab54
PHASE3 time SetPoint in blast -18°C Soft Manual half load
80min
0min
240min
Ab55
PHASE1 time SetPoint blast -18°C Hard Manual half load
80min
0min
240min
Ab56
PHASE2 time SetPoint blast -18°C Hard Manual half load
80min
0min
240min
Ab57
PHASE3 time SetPoint blast -18°C Hard Manual half load
80min
0min
240min
Label
Defrosting SetPoint
Default
MIN
MAX
Sc01
Initial SetPoint in defrosting cycle with high load
30°C
-60°C
100°C
Sc02
Final SetPoint in defrosting cycle with high load
12°C
-60°C
100°C
Sc03
Defrosting cycle duration with high load
360min
0min
999min
Sc04
Defrosting cycle initial SetPoint with medium load
25°C
-60°C
100°C
Sc05
Final SetPoint in defrosting cycle with medium load
12°C
-60°C
100°C
Sc06
Defrosting cycle duration with medium load
240min
0min
999min
Sc07
Initial SetPoint in defrosting cycle with low load
20°C
-60°C
100°C
Sc08
Final SetPoint in defrosting cycle with low load
12°C
-60°C
100°C
Sc09
Defrosting cycle duration with low load
60min
0min
999min
Sc10
Fan speed during phase1
5
0
5
Sc11
Fan speed during phase2
5
0
5
Sc12
Fan speed during phase3
5
0
5
Sc13
Fan speed during phase4
5
0
5
Sc14
Fan speed during phase5
5
0
5
Sc15
Dead zone in defrosting cycle
1°C
0°C
10°C
Sc16
Hot hysteresis in defrosting cycle
2°C
0°C
10°C
Sc17
Cold hysteresis in defrosting cycle
2°C
0°C
10°C
Sc18
Storage setpoint in defrosting cycle
3°C
-60°C
100°C
Sc19
Set humidity during phase1
0
0
5
Sc20
Set humidity during phase2
0
0
5
Sc21
Set humidity during phase3
0
0
5
Sc22
Set humidity during phase4
0
0
5
Sc23
Set humidity during phase5
0
0
5
Sc24
Set humidity during storage
0
0
5