8
Cleaning
DANGER!
Mains voltage!
– Before beginning with cleaning work, disconnect
the mains plug and protect the device against being
unintentionally switched back on!
– Do not allow any liquids to flow into the device.
– Indicate cleaning work with warning signs.
– Put safety equipment back into operation after
cleaning work.
8.1 Cleaning grinding elements
To facilitate cleaning, the grinding chamber, bottom sieve and cross
beater can all be removed. For this, see Chapter
the grinding elements’ on page 24.
Before reinserting the grinding components, it is essential to ensure that
both the motor shaft and the mounting bore hole of the cross beater
have been cleaned.
8.2 Cleaning the funnel
To better clean the funnel, the splash guard can be removed.
To do so, proceed as follows:
n
Remove the screw (S)
n
Loosen the two screws (L)
n
Slide the splash guard (R) gently backwards.
n
Lift the splash guard (R) up and out of the funnel
Cleaning
- 29 -
Содержание 16.60 0 Series
Страница 15: ...3 8 Collecting vessel volume 5000 ml or 30000 ml 3 9 Protection class IP41 Technical data 15 ...
Страница 19: ...DANGER Mains voltage Changes to the connection line may only be made by a qualified person Installation 19 ...
Страница 39: ...14 Safety logbook Date Maintenance Repair Name Signature Safety logbook 39 ...
Страница 41: ......