/ / FKL PUMP SERIES / / /
10
4.3
Moving With Crane
WARNING
Falling Parts
Death from crushing, severe pinching of extremities, material
damage.
►
Only use suitable means of conveyance and hoists. Informa-
tion on the pump weight can be found on the pump's rating
plate as well as in the
Order-Related Documents
in the at-
tached documents.
►
Do not lift the pump unit at the eyebolt on the motor or the
pump to move because these eyebolts are not designed for
the total weight of the pump unit.
►
Do not leave the pump in a raised position for longer than
necessary.
►
Ensure that the area below the pump is clear of people.
WARNING
Swinging Parts
Crushing and serious injuries.
►
Start and stop the crane with pump smoothly.
►
Ensure that the danger zone of the pump is clear of people.
Auxiliary Equipment
Hoists: round slings tested in accordance with DIN EN 1492-1
and 1492-2
Preparation
►
Remove load-securing devices.
Procedure
1.
Warning:
Round sling damage and tearing. Death from
crushing, severe pinching, material damage.
►
Do not lay the round sling over any sharp edges or cor-
ners.
Wrap the round sling around the gear motor; see
"Moving with round sling," page 10
.
2. Wrap the other end of the round sling around the pump cas-
ing; see
Fig. 10, "Moving with round sling," page 10
.
3. For double shaft seal:
Note:
Round sling compresses sealing water tubes. Material
damage to double shaft seal.
►
Do not lay the round sling on the sealing water tubes.
4. Guide both loops to the crane hook, rotate, and hook over
the hook to ensure that the belt will not slip on the hook.
5. Position the center of gravity to ensure that the pump is lift-
ed horizontally.
6. Lift the pump.
.
Fig. 10
Moving with round sling
5
Storage
5.1
Pump Storage Conditions
Store the pump as follows:
– Dry, in low humidity
– Protected against frost and heat, optimally at a temperature
of 20°C to 25°C
– Ventilated
– Dust-free
►
All movable pump parts must be rotated every three
months.
5.2
Long-Term Storage
For a storage time of longer than six months, heed the follow-
ing:
►
The shaft seals must be completely removed and stored sep-
arately before long-term storage of the pump.
See
Chapter 10.8, "Pump Casing Removal," page 16
and
Chapter 5.2.1, "Storage of Elastomers," page 10
5.2.1
Storage of Elastomers
Store the elastomers as follows:
– Storage temperature b5°C and +20°C
– Relative air humidity below 70%
– No direct sunlight
– Deformation-free storage
5.3
Recommissioning
►
After long-term storage and before commissioning, check
seals, bearings and oil level.