Emergency operation
OPERATION WITHOUT THE REMOTE CONTROLLER
• Emergency operation allow the air conditioner to be started or stopped when the infrared remo-
te controller is not available or the batteries are low.
• To access the emergency button, you have to remove the decorated board (the one with the
"HOKKAIDO" logo on it) before: holding it on both sides, let it slide downwards.
• When the air conditioner is OFF, shortly press the emergency button to turn ON the appliance.
• Operation will start in “AUTO” mode, and the set temperature value will be 24°C.
• When the air conditioner is ON, shortly press the emergency button to turn OFF the appliance.
• The position of the emergency operation (also for "TEST RUN mode) switch is pointed out in
the picture above.
“TEST RUN” Mode
• To start operation in "TEST RUN" mode, the emergency run switch (see above) must be hold
pressed
for more than 4 seconds
; the buzzer on the indoor unit will beep twice to indicate that
the air conditioner has entered the "TEST RUN" mode.
• The "TEST RUN" mode will last for no more than 15 minutes; after this time has elapsed, the air
conditioner will automatically switch to normal operation.
• During "TEST RUN" mode operation, the indoor unit can receive signals from the infrared
remote controller.
• You can also stop operation in "TEST RUN" mode before 15 minutes have elapsed: shortly
press the emergency run switch on the indoor unit, or press the ON/OFF button on the infrared
remote controller.
Monosplit ON/OFF models:
HKEJ 261 G, 351 G
Monosplit ON/OFF models:
HKEJ 261 G, 351 G
Emergency operation button
(also for "TEST RUN" mode)