LED display panel on the Indoor Unit
OUTLINE OF PARTS AND FUNCTIONS
Monosplit ON/OFF models:
HKEJ 261 G, 351 G
Front panel
Air filter
Decorated board
Motorized flap
(for vertical distribution)
Manual louvers
(for horizontal distribution)
"PAUSE" Indicator
"RUN" Indicator
It lights up to indicate that the
unit is operating:
AUTO (Automatic)
HEAT (Heating)
COOL (Cooling)
SWEEP (Fan only)
DRY (Dehumidifying).
It lights up during automatic
defrosting, or when the pre-
heating function for the indoor
heat exchanger is active (i.e.
when operation in Heating
mode starts).
ON/OFF Switch
For emergency opera-
tion in AUTO mode (if
the remote controller
is not available). Press
it again to stop the
unit.
"TIMER" Indicator
It lights up to indicate
that the unit's operation
has been programmed
by the Timer.
"AIR REFRESH" Indicator
It refers to a function which
is unavailable on these models.
Set temperature display
The desired temperature value is
displayed, as set by the User
through the infrared remote
controller.
Current indoor fan speed setting indicator
Indoor fan is set at "HIGH" speed
Indoor fan is set at "MEDIUM" speed
Indoor fan is set at "LOW" speed
NOTES:
If the current indoor fan speed setting indicator is flashing, this means that
"AUTO" fan speed has been selected.
1. Do not put fingers or sticks into the air inlet or air outlet of the indoor unit.
2. Touching the indoor fan which rotates at high speed, may result in serious injuries. Moreover the
aluminium fins on the heat echanger are sharp-edged. As a consequence, particular attention must
be observed when the front panel of the indoor unit has been opened for maintenance or air filters
cleaning. It is strongly adviced to switch off the main power line and wait some minutes before
carrying on the inspection work.
3. If the "RUN" indicator flashes, this means that a malfunction has occurred. In such cases, it is
required to contact a Service Agent.