Fig.12
CONNECTION OF WIRES
1. Indoor Unit
• Push the decorated board downward and move it away,
open the front panel by pushing it upward.
• Detach the electric control cover and pressure plate of
lead wire.
• Connect the connecting wires of the unit separately to
the corresponding terminals, and fix the terminals (Fig. 13).
• Butt the signal control wire.
• Press tightly the connecting wires of the units with pressure
plate of lead wire.
• Close the connection lid and screw it tightly.
• Close the front panel and reinstall the decorated board.
• For the details, please refer to "How to clean the air
filters" in the "User's Manual".
2. Outdoor Unit
• Loose off the screws and remove the electronic
device lid.
• Dismantle the pressure plate of wire fastener.
• Connect the connecting wires of the unit to the
corresponding terminal, and fix the terminals (Fig. 13).
• Butt the signal control wire.
• Press tightly the connecting wires of the unit with
pressure plate.
• Remount the electronic device lid to the original
position.
• RW type lead wire is used for power cord.
• If User wants to prolong or replace the power wire,
please do it according to the table.
• Ensure that wire connections are carried out according
to the wiring diagram of the air conditioner.
HKEJ 261 G
HKEJ 351 G
Fig.11
Fig.13