![Frigidaire FNGB90JFUW Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/frigidaire/fngb90jfuw/fngb90jfuw_user-manual_116318031.webp)
BURNER
Ø BYPASS 1/100 MM
Oven
54
Grill
-
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
KW
REDUCED POWER KW
INJECTOR MARK
1/100 MM
Triple Crown
3.8
1.8
146
Rapid
2.9
1.1
119
Semi-rapid
1.85
0.45
96
Auxiliary
0.95
0.35
70
Oven
3.9
1.5
136
Grill
3.0
-
126p
Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL
POWER KW
GAS RATE G/H REDUCED POW-
ER KW
INJECTOR MARK
1/100 MM
Triple Crown
4.0
290.9
1.8
101o
Rapid
3.0
218.1
1.1
88
Semi-rapid
1.9
138.2
0.43
71
Auxiliary
0.95
69.1
0.35
50
Oven
3.9
283.6
1.5
95
Grill
3.0
218.1
-
88
Gas connection
The gas pipe in the appliance has two
endings. You can connect the gas supply to
either one of them. The pipe that is not
used must be clogged with the pipe closer,
which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible
metallic pipes, make sure they do not come
in touch with mobile parts and they are not
squeezed.
31
INSTALLATION
Содержание FNGB90JFUW
Страница 39: ......
Страница 40: ...867354468 A 492020 ...