Section 3 Electronic Control Testing
3-30
Electric and Gas dryers; selector LEDs do not light.
Note: Always check wiring to the components.
Selector LEDs do
not light.
Defective interface
board.
Do any of the LEDs light
Check the wiring harness between
the control board and the interface
board.
No.
Repair or
replace harness.
Yes.
Defective
harness.
Good
harness.
Replace the interface
board. If this does not
correct the problem,
replace the control
board.