Section 3 Electronic Control Testing
3-25
Electric dryer not heating
properly.
Electric dryers not heating properly (Possible E 5b)
Note: Always check wiring to the components.
Program the dryer for a Normal
Cycle with High Temp and touch
Start . Measure the voltage drop
between L1 and L2 at the terminal
block.
Below 215 VAC.
Have customer
check house wiring.
Measure the voltage drop
between two terminals of the
heating element.
Not the same as
between L1 & L2.
Above 215 VAC.
Check for poor
connections in the
dryer heating circuit.
The same as
between L1 & L2.
Check the resistance of the
control thermistor at room
temperature.
50,000 Ohms +/-
10%.
Defective electronic
control.
Defective
thermistor.
More or less than
50,000 Ohms +/- 10%.