background image

USE & CARE MANUAL

THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY

STANDARD POWER SUPPLY CORD WITH A TEST-RESET FUNCTION

READ AND SAVE THESE INSTRUCTIONS

    AIR CONDITIONER

    

MULTI-STEP SPEED ELECTRONIC CONTROLS

                                                                  

 

                                                                                                                                                   P/N:819042150-01 

Содержание 819042150-01

Страница 1: ...UAL THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER MULTI STEP SPEED ELECTRONIC CONTROLS P N 819042150 01 ...

Страница 2: ...consequential damages so this limitation or exclusion may not apply to you 2 Service calls which do not involve malfunction or defects in workmanship or material or for appliances not in ordinary household use The consumer shall pay for such service calls 3 Damages caused by services performed by persons other than authorized Frigidaire servicers use of parts other than Frigidaire Genuine Renewal ...

Страница 3: ...t passing through the evaporator during normal operation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Pinging or Swishing Droplets of water hitting the condenser during normal operation may cause pinging or swishing sounds V...

Страница 4: ...d To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug and a current leakage detection device for protection against shock firehazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breake...

Страница 5: ...rect operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yoursel...

Страница 6: ...O CHANGE TEMPERATURE SETTING YOU WILL SEE DO THIS PRESS TO RAISE PRESS TO LOWER NOTE Tap or hold either up or down button until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 60 F 15 and 90 F 32 If you want the display to read the actual room temperature See To Operate on Fan Only section on Page 7 TO ADJUST FAN SPEEDS YOU WILL SEE...

Страница 7: ...g efficiency You can choose any fan speed TO USE THE ENERGY SAVER FEATURE YOU WILL SEE DO THIS PRESS MODE BUTTON CHOOSE ENERGY SAVER NOTE In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor NOTE Fan starts at High Speed ...

Страница 8: ...led at any time during operation by again pressing the Sleep button CHECK FILTER FEATURE YOU WILL SEE NOTE This feature is a reminder to clean the Air Filter See Care and Cleaning for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Check NOTE For Delay Stop the unit must be in the ON position LIGHT ON LIGHT ON LIGHT O...

Страница 9: ...cuit breaker tripping The fan will continue to run during this time The control will maintain the set temperature within 2 F between 60 F and 90 F degrees The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds YOU WILL SEE 9 familiar with Fresh Air V...

Страница 10: ...dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaner wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditione...

Страница 11: ...ESET button Reset to a lower temperature Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Vent set at OPEN position Set vent at CLOSED position for maximum cooling Air direction louvers positioned improperly Position louvers for better air distribution Front of unit is blocked by drapes blinds furniture etc restricts ...

Отзывы: