ELECTRICAL INSTALLATION

The following are specific requirements  for

proper and safe electrical installation of your laundry center.
Failure to follow these instructions can create electrical shock
and/or a fire hazard.

This appliance MUST be properly grounded.

Electrical shock can result if the laundry center is not properly
grounded. Follow the instructions in this manual for proper
grounding.

Do not use an extension cord with this laundry

center. Some extension cords are not designed to withstand
the amounts of electrical current this laundry center utilizes
and can melt, creating electrical shock and/or fire hazard.
Locate the laundry center within reach of the receptacle for
the length power cord to be purchased, allowing some slack
in the cord. Refer to the pre-installation requirements in this
manual for the proper power cord to be purchased.

A U.L. approved strain relief must be installed

onto power cord. If the strain relief is not attached, the cord
can be pulled out of the laundry center and can be cut by any
movement of the cord, resulting in electrical shock.

Do not use an aluminum wired receptacle

with a copper Wired power cord and plug (or vice versa). A
chemical reaction occurs between copper and aluminum and
can cause electrical shorts.

The proper wiring and receptacle is a copper wired
power cord with a copper wired receptacle OR aluminum
wired power cord with an aluminum wired receptacle.

NOTE: Laundry centers operating on a 208 volt power supply
will have longer drying times than laundry centers operating on
a 240 volt power supply.

GROUNDING REQUIREMENTS

 

 Improper connection of the equipment

grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to whether
the appliance is properly grounded.

For a grounded, cord-connected laundry center:
1. The laundry center 

MUST 

be grounded. In the event of

malfunction or breakdown, grounding will reduce the risk of
electrical shock by a path of least resistance for electrical
current.

2. If your laundry center is equipped with a power supply cord

having an equipment-grounding conductor and a grounding
plug, the plug 

MUST

 be plugged into an appropriate, copper

wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician.  

Do not modify plug provided

with the appliance.

For a permanently connected laundry center:
The laundry center MUST be connected to a grounded metal,
permanent wiring system; or an equipment grounding conductor
MUST be run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the appliance.

8

 

 

Improper connection of the equipment

grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.

For a grounded cord connected laundry center:
1. The laundry center 

MUST 

be grounded. In the event of

malfunction or breakdown, grounding will reduce the risk of
electrical shock by providing a path of least resistance for
the electrical current.

2. Since your laundry center is equipped with a power supply

cord having an equipment-grounding conductor and a
grounding plug, the plug 

MUST 

be plugged into an

appropriate outlet that is properly installed and grounded in
accordance with all codes and ordinances. If in doubt, call a
licensed electrician.

1. The laundry center is equipped with a three-prong (grounding)

plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
the plug.

Non-Canadian ELECTRIC Laundry Center

ALL GAS Laundry Centers

DANGER

DANGER

ALL ELECTRIC Laundry Centers

Canadian ELECTRIC Laundry Center

WARNING

WARNING

WARNING

WARNING

WARNING

Содержание 27

Страница 1: ...ric Dryer Use and Care Guide CENTRO DE LAVANDERÍA de 27 69 cm de ancho Lavadora Secadora eléctrica Manual de Uso y Cuidado Models Modelos P N 134897500A 0804 Made in USA Installation Instructions Instrucciones para la instalación Washer Dryer ...

Страница 2: ...h as restaurants or beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any el...

Страница 3: ...o the power supply cord is accessible when the laundry center is in an installed position WATER SUPPLY REQUIREMENTS Hot and cold water faucets MUST be installed within 42 inches 106 68 cm of your laundry center s water inlet The faucets MUST be 3 4 inch 1 9 cm garden hose type so inlet hoses can be connected Water pressure MUST be between 10 and 120 pounds per square inch maximum unbalance pressur...

Страница 4: ...and vent hood for proper operation The maximum length of the exhaust system depends upon the type of duct used number of elbows and type of exhaust hood The maximum length for both rigid and semi rigid duct is shown in the chart below MAXIMUM LENGTH OF 4 INCH 10 2 CM DIAMETER SEMI RIGID METAL DUCT EXHAUST DUCT LENGTHS Number of 90 Turns MAXIMUM LENGTH OF 4 INCH 10 2 CM DIAMETER RIGID METAL DUCT EX...

Страница 5: ...d metal duct work should be used Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint Compression or crimping of the exhaust system will cause an increase in vent restriction GAS SUPPLY REQUIREMENTS 1 Installation MUST conform...

Страница 6: ...16 IN 29 5 CM 1 7 8 IN 4 76 CM 3 IN 9 52 CM 9 3 8 IN 23 81 CM 41 IN 104 77 CM 29 7 16 IN 74 77 CM 27 IN 68 58CM DRAIN OUTLET REAR WATER INLETS REAR VENT 5 IN 13 33 CM GAS SUPPLY PIPE REAR 43 IN 109 22 CM 54 5 16 IN 137 95 CM 75 IN 191 77 CM 43 IN 109 22 CM ELECTRICAL CONNECTION 12 IN 31 75 CM ROUGH IN DIMENSIONS ...

Страница 7: ...clamps form a standpipe to prevent water syphoning DO NOT REMOVE THESE CLAMPS 6 Carefully move the laundry center to within 4 feet 1 22 m of the final location to begin the installation MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstr...

Страница 8: ...d laundry center 1 The laundry center MUST be grounded In the event of malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your laundry center is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is ...

Страница 9: ...ANADIAN ELECTRIC Laundry Center NEUTRAL GROUND WIRE 1 Remove the screw securing the terminal block access cover to the rear panel and remove cover 2 Install a U L approved strain relief connector in the entry hole on the back panel 3 Remove the neutral ground wire from the green ground screw located above the termial block 4 Insert a NEMA 14 30 Type ST or SRDT U L approved power cord through the s...

Страница 10: ...he ground Gently set the laundry center back down to allow the rear legs to self adjust Place a level on top of the washer Check it side to side then front to back Screw the front leveling legs up or down to ensure the laundry center is resting solid on all four legs no rocking of the laundry center should exist NOTE Keep the leg extension at a minimum to prevent excessive vibration 7 GAS CONNECTI...

Страница 11: ...er make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air WARNING WARNING REPLACEMENT PARTS If replacement parts are needed for your laundry center contact the source where you purchased your laundry center Destroy the carton plastic bags and meta...

Страница 12: ...explosión o para evitar daños materiales lesiones personales o la muerte No almacene ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de éste o de cualquier otro artefacto eléctrico QUEDEBEHACERSIPERCIBEOLORAGAS No trate de encender ningún artefacto eléctrico Notoqueningúninterruptoreléctrico nouseningúnteléfonoensuedificio Haga salir a todos los ocupantes de la habitaci...

Страница 13: ...ipo NEMA 10 30 SRDT calificado para CA mínima de 240 voltios 30 A con 3 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Vea CONEXIONES ELÉCTRICAS PARA UN SISTEMA TRIFILAR Tetrafilar la secadora DEBE emplear un cable de alimentación eléctrica de 4 conductores tipo NEMA 14 30 SRDT o ST según se especifique calificado ...

Страница 14: ...LIDA Preferido Número de Codos a 90 LARGO MÁXIMO del Conducto Metálico Rigido de 4 10 2 cm de Diámetro 4 10 2 cm Apersianada LARGO MÁXIMO del Conducto Metálico Flexible de 4 10 2 cm de Diámetro 6 35 cm 2 0 30 pies 9 14 m 22 pies 5 49 m 1 22 pies 6 71 m 14 pies 4 27 m 2 16 pie 4 88 m 10 pies 3 05 m 3 NO RECOMENDADO INCORRECT INCORRECT REQUERIMIENTOS DEL SISTEMA DE ESCAPE Utilice solamente ductos me...

Страница 15: ...gido 8 pilgadas 20 32 cm de longitud y 4 pulgadas 10 16 cm de diàmetro 1 ducto acodado hacia abajo y un ducto acodado hacia la derecha 4 Hacia la derecha ducto rigido 8 pulgadas 20 32 cm de longitud y 4 pulgadas 10 16 cm de diàmetro 1 ducto acodado hacia abajo y un ducto acodado hacia la derecha Aungue un sistema vertical sea aceptable algunas circunstancias atenuantes pueden afectar el funcionami...

Страница 16: ... 11 7 16 IN 29 5 CM 41 IN 104 77 CM 29 7 16 IN 74 77 CM 27 IN 68 58CM DRAIN OUTLET REAR WATER INLETS REAR VENT 1 7 8 IN 4 76 CM 5 IN 13 33 CM GAS SUPPLY PIPE REAR 43 IN 109 22 CM 54 5 16 IN 137 95 CM 75 IN 191 77 CM 43 IN 109 22 CM ELECTRICAL CONNECTION 12 IN 31 75 CM LINA DE ALIMENTATION DE GAS ATRAS CONEXIÓN ES ELÉCTRICA S ENTRADAS DE AGUA ATRAS SALIDA AL DRENAJE ATRAS ...

Страница 17: ...AM SHIPPING PAD DRAIN HOSE POWER CORD IF EQUIPPED SHIPPING CARTON CORNER POSTS Bloque espaciador de plàstico Perno de embarque Espuma protectora de embareque Manguera de desagüe Bloque de embarque Cordon eléctrico si viene el equipo INSTALACIÓN EN CASAS MÓVILES 1 El tubo de escape de la secadora DEBE ser instalado hacia el exterior El escape debe colocarse en la parte exterior y no debajo de la ca...

Страница 18: ...equipadaconuncordóneléctricoqueposee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra dicho enchufe DEBE ser conectado a un tomacorriente adecuado debidamente instalado y puesto a tierra de acuerdo con todos los códigos y reglamentos locales Sitienealgunadudaconsulteaunelectricistaprofesional No modifique el enchufe proporcionado la aplicación Para una lavanderia conectad...

Страница 19: ...alicates Conecte con cuidado el tubo superior de entrada a la llave de agua FRIA apriete a mano y luege apriete 2 3 vuelta con unos alicates NO ESTROPEE LAS ROSCAS NI APRIETE ESTAS CONEXIONES EXCESIVAMENTE Abra la llave del agua y compuebe que no haya fugas en ninguna de lasdos conexiones 5 Con cuidado mueve el centro de lavanderia hasta su ubicación definitiva para instalación final 6 Para verifi...

Страница 20: ...emásasegúresedequenohayanada talcomocajas ropas etc queobstruyaelflujodelairedecombustiónyventilación 13 Vuelva a instalar el panel de acceso delantero de la seadora 14 Haga funcionar la secadora durante un ciclo completo para comprobarsubuenfuncionamiento NOTA En las secadoras a gas antes de encender el quemador esnecesariopurgarelairedelatuberíadelgas Sielquemador no enciende dentro de 45 segund...

Отзывы: