Frigidaire 27 Скачать руководство пользователя страница 5

60 SQ. IN.

(387.1 SQ. C M)

60 SQ. IN.

(387.1 SQ. C M)

Closet Door

5

0 IN.

(0 CM)

DRYER

WASHER

0 IN.

(0 CM)

1 IN.

(2.54  CM)

0 IN.

(0 CM)

60 SQ. IN.

(387.1 SQ. C M)

60 SQ. IN.

(387.1 SQ. C M)

 

LOCATION OF YOUR LAUNDRY CENTER

DO NOT INSTALL YOUR LAUNDRY CENTER:

1.In an area exposed to dripping water or outside weather conditions.
2.In an area where it will come in contact with curtains or drapes.
3.On carpet. Floor 

MUST 

be solid with a maximum slope of 1 inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET

1.A laundry center installed in a bedroom, bathroom, recess or closet, 

 MUST 

be exhausted outdoors.

2.No other fuel burning appliance shall be installed in the same closet as the 

Gas 

laundry center.

3.Your laundry center needs the spacearound it for proper ventilation.

DO NOT INSTALL YOUR  LAUNDRY CENTER IN A CLOSET WITH A

 

 SOLID DOOR.

4.A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required.

Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the  full
length of the door is acceptable.

5.The following illustrations show minimum clearance dimensions and air openings for proper operation in a recess or closet

installation.

The laundry center may be exhausted four (4) ways with rear

flush 

installation:

1.

Straight back

2.

Down 

(8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid

duct and 1 elbow down)

3.

Left 

(8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid

duct, 1 elbow down and 1 elbow left)

4.

Right 

(8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid

duct, 1 elbow down and 1 elbow right)

Although vertical orientation of the exhaust system is acceptable,
certain extenuating circumstances could affect the performance
of the dryer:

Only the rigid metal duct
work should be used.

Venting vertical through
a roof may expose the
exhaust system to down
drafts causing an
increase in vent
restriction.

Running the exhaust
system through an
uninsulated area may
cause condensation and
faster accumulation of
lint.

Compression or crimping
of the exhaust system
will cause an increase in
vent restriction.

GAS SUPPLY REQUIREMENTS

1.Installation 

MUST 

conform with local codes, or in the absence

of local codes, with the National Fuel Gas Code, ANSI  Z223.1
(latest edition) or in Canada, the current AN/CGA B149.

2.The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.If codes allow, flexible metal tubing may be used to connect

your dryer to the gas supply line. The tubing 

MUST 

be

constructed of stainless steel or plastic-coated brass.

4.The gas supply line 

MUST 

have an individual shutoff valve.

5.A 1/8   inch (0.32 cm) N. P. T. plugged tapping, accessible for

test gage connection, 

MUST 

be installed immediately

upstream of the gas supply connection to the dryer.

6.The dryer and its individual shutoff valve 

MUST 

be

disconnected from the gas supply piping system during any
pressure testing of the gas  supply piping system at test
pressures equal to or less than 1/2 psig  (3.45 kPa).

7.The dryer 

MUST 

be isolated from the gas supply piping system

by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.45 kPa).

To exhaust up, add an 11 inch (27.94 cm) length of standard 4
inch (10.16 cm) diameter duct and a 90° elbow. The unit will
be positioned about 4½

 

inches (11.43 cm) away from the wall

(flush to wall exhausting may be done by going below the dryer
then sideways).

An exhaust hood positioned to line up with the dryer exhaust
can be installed directly through the outside wall. To exhaust to
the side or down, add an 8 inch (20.32 cm) length of standard 4
inch (10.16 cm) diameter duct and a 90°  elbow.

Содержание 27

Страница 1: ...ric Dryer Use and Care Guide CENTRO DE LAVANDERÍA de 27 69 cm de ancho Lavadora Secadora eléctrica Manual de Uso y Cuidado Models Modelos P N 134897500A 0804 Made in USA Installation Instructions Instrucciones para la instalación Washer Dryer ...

Страница 2: ...h as restaurants or beauty salons etc For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any el...

Страница 3: ...o the power supply cord is accessible when the laundry center is in an installed position WATER SUPPLY REQUIREMENTS Hot and cold water faucets MUST be installed within 42 inches 106 68 cm of your laundry center s water inlet The faucets MUST be 3 4 inch 1 9 cm garden hose type so inlet hoses can be connected Water pressure MUST be between 10 and 120 pounds per square inch maximum unbalance pressur...

Страница 4: ...and vent hood for proper operation The maximum length of the exhaust system depends upon the type of duct used number of elbows and type of exhaust hood The maximum length for both rigid and semi rigid duct is shown in the chart below MAXIMUM LENGTH OF 4 INCH 10 2 CM DIAMETER SEMI RIGID METAL DUCT EXHAUST DUCT LENGTHS Number of 90 Turns MAXIMUM LENGTH OF 4 INCH 10 2 CM DIAMETER RIGID METAL DUCT EX...

Страница 5: ...d metal duct work should be used Venting vertical through a roof may expose the exhaust system to down drafts causing an increase in vent restriction Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint Compression or crimping of the exhaust system will cause an increase in vent restriction GAS SUPPLY REQUIREMENTS 1 Installation MUST conform...

Страница 6: ...16 IN 29 5 CM 1 7 8 IN 4 76 CM 3 IN 9 52 CM 9 3 8 IN 23 81 CM 41 IN 104 77 CM 29 7 16 IN 74 77 CM 27 IN 68 58CM DRAIN OUTLET REAR WATER INLETS REAR VENT 5 IN 13 33 CM GAS SUPPLY PIPE REAR 43 IN 109 22 CM 54 5 16 IN 137 95 CM 75 IN 191 77 CM 43 IN 109 22 CM ELECTRICAL CONNECTION 12 IN 31 75 CM ROUGH IN DIMENSIONS ...

Страница 7: ...clamps form a standpipe to prevent water syphoning DO NOT REMOVE THESE CLAMPS 6 Carefully move the laundry center to within 4 feet 1 22 m of the final location to begin the installation MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstr...

Страница 8: ...d laundry center 1 The laundry center MUST be grounded In the event of malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 If your laundry center is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is ...

Страница 9: ...ANADIAN ELECTRIC Laundry Center NEUTRAL GROUND WIRE 1 Remove the screw securing the terminal block access cover to the rear panel and remove cover 2 Install a U L approved strain relief connector in the entry hole on the back panel 3 Remove the neutral ground wire from the green ground screw located above the termial block 4 Insert a NEMA 14 30 Type ST or SRDT U L approved power cord through the s...

Страница 10: ...he ground Gently set the laundry center back down to allow the rear legs to self adjust Place a level on top of the washer Check it side to side then front to back Screw the front leveling legs up or down to ensure the laundry center is resting solid on all four legs no rocking of the laundry center should exist NOTE Keep the leg extension at a minimum to prevent excessive vibration 7 GAS CONNECTI...

Страница 11: ...er make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air WARNING WARNING REPLACEMENT PARTS If replacement parts are needed for your laundry center contact the source where you purchased your laundry center Destroy the carton plastic bags and meta...

Страница 12: ...explosión o para evitar daños materiales lesiones personales o la muerte No almacene ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de éste o de cualquier otro artefacto eléctrico QUEDEBEHACERSIPERCIBEOLORAGAS No trate de encender ningún artefacto eléctrico Notoqueningúninterruptoreléctrico nouseningúnteléfonoensuedificio Haga salir a todos los ocupantes de la habitaci...

Страница 13: ...ipo NEMA 10 30 SRDT calificado para CA mínima de 240 voltios 30 A con 3 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Vea CONEXIONES ELÉCTRICAS PARA UN SISTEMA TRIFILAR Tetrafilar la secadora DEBE emplear un cable de alimentación eléctrica de 4 conductores tipo NEMA 14 30 SRDT o ST según se especifique calificado ...

Страница 14: ...LIDA Preferido Número de Codos a 90 LARGO MÁXIMO del Conducto Metálico Rigido de 4 10 2 cm de Diámetro 4 10 2 cm Apersianada LARGO MÁXIMO del Conducto Metálico Flexible de 4 10 2 cm de Diámetro 6 35 cm 2 0 30 pies 9 14 m 22 pies 5 49 m 1 22 pies 6 71 m 14 pies 4 27 m 2 16 pie 4 88 m 10 pies 3 05 m 3 NO RECOMENDADO INCORRECT INCORRECT REQUERIMIENTOS DEL SISTEMA DE ESCAPE Utilice solamente ductos me...

Страница 15: ...gido 8 pilgadas 20 32 cm de longitud y 4 pulgadas 10 16 cm de diàmetro 1 ducto acodado hacia abajo y un ducto acodado hacia la derecha 4 Hacia la derecha ducto rigido 8 pulgadas 20 32 cm de longitud y 4 pulgadas 10 16 cm de diàmetro 1 ducto acodado hacia abajo y un ducto acodado hacia la derecha Aungue un sistema vertical sea aceptable algunas circunstancias atenuantes pueden afectar el funcionami...

Страница 16: ... 11 7 16 IN 29 5 CM 41 IN 104 77 CM 29 7 16 IN 74 77 CM 27 IN 68 58CM DRAIN OUTLET REAR WATER INLETS REAR VENT 1 7 8 IN 4 76 CM 5 IN 13 33 CM GAS SUPPLY PIPE REAR 43 IN 109 22 CM 54 5 16 IN 137 95 CM 75 IN 191 77 CM 43 IN 109 22 CM ELECTRICAL CONNECTION 12 IN 31 75 CM LINA DE ALIMENTATION DE GAS ATRAS CONEXIÓN ES ELÉCTRICA S ENTRADAS DE AGUA ATRAS SALIDA AL DRENAJE ATRAS ...

Страница 17: ...AM SHIPPING PAD DRAIN HOSE POWER CORD IF EQUIPPED SHIPPING CARTON CORNER POSTS Bloque espaciador de plàstico Perno de embarque Espuma protectora de embareque Manguera de desagüe Bloque de embarque Cordon eléctrico si viene el equipo INSTALACIÓN EN CASAS MÓVILES 1 El tubo de escape de la secadora DEBE ser instalado hacia el exterior El escape debe colocarse en la parte exterior y no debajo de la ca...

Страница 18: ...equipadaconuncordóneléctricoqueposee un conductor de puesta a tierra del equipo y un enchufe de puesta a tierra dicho enchufe DEBE ser conectado a un tomacorriente adecuado debidamente instalado y puesto a tierra de acuerdo con todos los códigos y reglamentos locales Sitienealgunadudaconsulteaunelectricistaprofesional No modifique el enchufe proporcionado la aplicación Para una lavanderia conectad...

Страница 19: ...alicates Conecte con cuidado el tubo superior de entrada a la llave de agua FRIA apriete a mano y luege apriete 2 3 vuelta con unos alicates NO ESTROPEE LAS ROSCAS NI APRIETE ESTAS CONEXIONES EXCESIVAMENTE Abra la llave del agua y compuebe que no haya fugas en ninguna de lasdos conexiones 5 Con cuidado mueve el centro de lavanderia hasta su ubicación definitiva para instalación final 6 Para verifi...

Страница 20: ...emásasegúresedequenohayanada talcomocajas ropas etc queobstruyaelflujodelairedecombustiónyventilación 13 Vuelva a instalar el panel de acceso delantero de la seadora 14 Haga funcionar la secadora durante un ciclo completo para comprobarsubuenfuncionamiento NOTA En las secadoras a gas antes de encender el quemador esnecesariopurgarelairedelatuberíadelgas Sielquemador no enciende dentro de 45 segund...

Отзывы: