owner's manual
3
Ⅰ
50℃
45℃
39℃
Pause
The Max. 48Hz
The Max. 60Hz
Accord to the
49℃
44℃
38℃
frequency in the instruction
3.
When the Priority Mode has been set, the first indoor unit will
work in Heating Mode that is Heating Priority, please refer to the
ITEM 1 for the control logic. If the first indoor unit is work in
Cooling Mode, that is the Cooling Priority Mode, please refer to
the ITEM 2 for the control logic;
4.
In terms of the settings only respond the Heating Mode, the
indoor unit will run in Heating Mode normally, if unit be run in the
Cooling Mode or air Supply Mode, the indoor unit will display
Mode Conflicting;
5.
In terms of the settings only respond the Cooling Mode, the
indoor unit will run in Cooling Mode or air supply mode normally,
if unit be run in the Heating Mode, the indoor unit will display
Mode Conflicting.
Features of heating operation
● Warm air will not be blown out immediately at the beginning of the
heating operation, after 3~5minutes (depends on the indoor and
outdoor temperature), until the indoor heat exchanger become
hot, then blows out warm air.
● During operation, the fan motor in the outdoor unit may stop
running under high temperature.
● During Fan operation, if other indoor Units are running on heating
mode, the fan may stop in order to prevent sending heat wind.
Defrost in the heating operation
● During heating operation, outdoor unit sometimes will frost. To
increase efficiency, the unit will start defrosting automatically
(about 2~10 minutes), and then water will be drained out from
outdoor unit.
● During defrosting, both the fan motors in the outdoor unit and
indoor unit will stop running.
Operation conditions
For proper performance, run the air conditioner under the
following temperature conditions:
Table.3-1
Protection Device
This protection device will stop the unit automatically in case
the air conditioner is on forced running mode. When protection
device is activated, running indicator light is lightened and
query light flashes. Protection device may start under the
following circumstances:
cooling operation:
● The air inlet or air outlet of outdoor unit is blocked.
● Strong wind is continuously blowing to the air outlet of the
outdoor unit.
heating operation:
● Too much dust and rubbish adhere to the dust filter in the
indoor unit
Power cut
● If power is cut during operation, stop all the operation
immediately.
● Power comes again. The operation indicator on the wire
controller flashes.
● Push the ON/OFF button again if you want to restart the
unit.
Mishanding in operation
In case of mishandling caused by lighting or mobile wireless,
please switch off the manual power off the manual power.
Push ON/OFF again when restarting.
Heating capacity
● The heating process is :absorb heat from outdoor, while
expel heat to indoor by hot pump. Once the outdoor
temperature drop down, heating capacity is degraded
correspondingly.
● It is command to equip with other warming facility, when
outdoor temperature is low.
● It is better to equip with additional purchase indoor
auxiliary heating device in paramos area where is in
particularly low outdoor temperature. (See Indoor Unit
Operation Manual for detail information)
Protective device may start if running the unit outside the
above condition, which will prevent the unit from operation.
DC compressor frequency-limited control
The Cooling ambient temperature T4 frequency-limited control:
Please switch off the power when protection device starts.
Do not restart until the problems are solved.
For the models with combination
of fixed frequency compressor
and inverter compressor:
For the models with only one
inverter compressor:
4.
TROUBLES AND CAUSES
Please see the above graph, the ambient condition is great affect
to the air conditioner, therefore, please install the outdoor unit in a
well-ventilated area prevent from cooling attenuation.
In case the following malfunctions, please switch off the
power and contact the local dealer. Incorrect ON/OFF
operation
Fuse or leakage protector is frequently broken.
Foreign matter or water falls in the unit.
NOTE
CAUTION
Temperature
Mode
Outdoor
temperature
Indoor
temperature
Room relative
humidity
Cooling mode
-5°C ~ 48°C
17°C ~ 32°C
below 80%
Heating mode
-15°C ~ 24°C
≤27°C
NOTE
Ⅰ
50℃
43℃
39℃
Pause
The Max. 62Hz
The Max. 70Hz
Accord to the
49℃
42℃
38℃
frequency in the instruction
NOTE