In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

 

 

Be sure the air conditioner is grounded.

 

In  order  to  avoid  electric  shock,  make  sure  that  the  unit  is 
grounded  and that the earth wire is not connected to  gas or 
water pipe, lightning conductor or telephone earth wire.

 

 

In order to avoid injury, do not remove the fan guard of 
the outdoor unit.

 

 

Do not operate the air conditioner with a wet hand.

 

An electric shock may happen.

 

 

Do not touch the heat exchanger fins.

 

These fins are sharp and could result in cutting injuries.

 

 

After a long use, check the unit stand and fitting for 
damage.

 

If damaged, the unit may fall and result in injury.

 

 

To  avoid  oxygen  deficiency,  ventilate  the  room 
sufficiently  if  equipment  with  burner  is  used  together 
with the air conditioner.

 

 

Arrange the drain hose to ensure smooth drainage. 

Incomplete drainage may cause wetting of the building, 
furniture etc.

 

2.

 

PARTS NAMES

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig.2-1

 

 

Never expose little children, plants or animals directly to 
the air flow.

 

Adverse  influence  to  little  children,  animals  and  plants  may 
result.

 

 

Notice to avoid places where operation noise may easily 
be spread away or be enhanced.

 

 

Noise  can  be  amplified  by  anything  blocking  the  air 
outlet of outdoor unit.

 

 

Choose  a  proper  place  that  the  noise  and  hot  or  cold  wind 
blown out of  the  outdoor  unit will not bring inconvenience  to 
your neighbors and not affect the growth or animal or plant.

 

 

Do  not  allow  a  child  to  mount  on  the  outdoor  unit  or 
avoid placing any object on it.

 

Falling or tumbling may result in injury.

 

 

Do  not  operate  the  air  conditioner  when  using  a  room 
fumigation - type insecticide.

 

Failure  to  observe  could  cause  the  chemicals  to  become 
deposited  in  the  unit,  which  could  endanger  the  health  of 
those who are hypersensitive to chemicals.

 

 

Do  not  place  appliances  which  produce  open  fire  in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It  may  cause  incomplete  combustion  or  deformation  of  the 
unit due to the heat.

 

 

Do  not  install  the  air  conditioner  at  any  place  where 
flammable gas may leak out.

 

If  the  gas  leaks  out  and  stays  around  the  air  conditioner,  a 
fire may break out.

 

 

The  appliance is not  intended for use by young children 
or infirm persons without supervision.

 

 

Young children should be supervised to ensure that they 
do not play with the appliance

.

 

 
 

 

 

All  the  pictures  in  this  manual  are  for  explanation  purpose 
only, There may be slightly  different  from  the  air conditioner 
you  purchased  (depend  on  model).  The  actual  shape  shall 
prevail.

 

 

To avoid danger, never put sticks or other objects into it.

 

 

Please preheat the air conditioner for at least 12 hours before 
operation. Do not switch off the power if you need to stop the 
unit  for  24h  or  shorter  time.  (This  is  to  heat  the  crank  case 
heater to avoid the compulsive start of compressor.)

 

 

Make sure the air  inlet and outlet are  not blocked,  or  it may 
degrade the performance of air conditioner or start up protec- 
tor which will stop the unit from running.

 

 

 

 

 

3.

 

OPERATION AND PERFORMANCE

 

 

Cooling and heating operation of Kaysun inverter central A/C

 

 

●  The  indoor  unit  of  this  air  conditioner  can  be  controlled  solely, 

and the indoor unit in the same system can not run cooling and 
heating at the same time.

 

 

●  When  the  Cooling  and  Heating  operation  confront  with  each 

other, please determine the problem according to the settings of 
outdoor unit Mode dial code SW5.

 

 

1. 

When  set  as  the  Heating  Priority  Mode,  the  indoor  unit  on 

Cooling Mode would stop and there will be Standby or No Priority 
displayed  on  the  control  panel.  Those  indoor  units  which  are 
running on Heating Mode will run continuously. 

 

2. 

When the Cooling Priority Mode has been set, the indoor unit 

on  Heating  Mode  would  stop  and  there  will  be  Standby  or  No 
Priority displayed on the control panel. Those indoor units which 
are running on Cooling Mode will run continuously; 

  

NOTE 

 

 

 

 

 

 

 

 

1

 

Air inlet (Both in Left and right sides, as well as in rear side. )

 

2

 

Refrigerant pipe connective opening

 

3

 

Wires outlet (Some types have not wires outlet)

 

4

 

Fixed foot

 

5

 

Air outlet (Heat air to be blows out in the cooling operation,

 

vice versa while the heating. )

 

 

Содержание Kaysun K2UF-280 DN3

Страница 1: ...280 DN3 K2UF 335 DN3 K2UF 400 DN3 K2UF 450 DN3 Original instructions Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep...

Страница 2: ......

Страница 3: ...ult in a water leakage electric shock and fire To avoid electric shock fire or injury or if you detect any abnormality such as smell of fire turn off the power supply and call your dealer for instruct...

Страница 4: ...deformation of the unit due to the heat Do not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out...

Страница 5: ...tion The air inlet or air outlet of outdoor unit is blocked Strong wind is continuously blowing to the air outlet of the outdoor unit heating operation Too much dust and rubbish adhere to the dust fil...

Страница 6: ...ing and heating mode FAN mode stops to avoid cold air blown out The master unit with slave units for different purposes when abnormal accident happens the director will illustrate Indoor unit Bad odor...

Страница 7: ...re poweredonfortherecovery 20 P0 Inverter upper temp protection 21 P1 Hi pressure protection 22 P2 Lo pressure protection power error 3 phase protector error P2protectionoccur andthenvanish within one...

Страница 8: ...discharge temp Actual value 15 Fixed frequency 2 air discharge temp Actual value 16 Inverter current Actual value 17 Fixed frequency 1 current Actual value 18 Fixed frequency 2 current Actual value 19...

Страница 9: ...e 0 1 MPa 21 The limitation of Indoor unit proformed mode 0 1 2 3 4 22 Indoor unit qty Actual value 23 The last time error or protective code Without protection or error displays as 00 24 Spot inspect...

Страница 10: ...owner s manual 7...

Страница 11: ...MDV10U 001FW 16126000000245...

Страница 12: ......

Отзывы: