42
PB
TROUBLESHOOTING
Compressor Or Outdoor Fan Does Not Operat At All
Figure 716
Compressor or outdoor fan does not operate at all.
Re-input after power of f
Set the desired temperature of remote controller to be lower by 2°C or
over than room temperature, and start the cooling operation.
Does not operate at all.
Repeat running/stopping
at a short time period.
Temperature sensor
open/short check
Thermistor and evaporator
surface contact check.-
Clearance is needed (5mm).
Connector check
(Contact & power)
Connector check
(Contact & power)
Disconnection/short
circuit check of
connecting wire
OLP/High pressure
switch/Low pressure
switch check
Electric wire connection
check for outdoor side
Operation mode
(dehumidifying) check
Compressor & motor
detail check
PCB assy check
Check:
Temperature sensing circuit
Relay output
Insulation resistance
Coil resistance
Capacitor capacity
Compressor OLP
Содержание UCT08A10A
Страница 14: ...14 OPERATION Control Panel mode and or HEAT...
Страница 44: ...44 WIRING DIAGRAMS ChillPremierCCF Figure 801 Models CCF05A10A CCF06A10A CCF08A10A CCF10A10A CCF12A10A E...
Страница 45: ...45 WIRING DIAGRAMS ChillPremierCCW Models CCW06B10A CCW24B30A Figure 802...
Страница 46: ...46 WIRING DIAGRAMS ChillPremierCCW CCW08B10A odels Models CCW10B10A CCW12B10A CCW15B10A Figure 803...
Страница 73: ...73 THIS PAGE LEFT INTENTIONALLY BLANK...