This INSTALLATION MANUAL briefly outlines where
and how to install the air conditioning system. Please
read over the entire set of instructions for the indoor
and outdoor units and make sure all accessory parts
listed are with the system before beginning.

1. TYPE OF COPPER PIPE AND INSULATION MATERIAL

Copper tubing for connectin the outdoor unit to the indoor
unit and insulation material is available for purchase locally.
When you purchase them, please specify the following.

A. Deoxidized annealed copper pipe for refrigerant piping as:

STANDARD ACCESSORIES

The following installation accessories are supplied. Use them as
required.

ELECTRICAL REQUIREMENT

Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.

The following items are necessary to install this air conditioner. (The
items are not included with the air conditioner and must be purchased
separately.)

ADDITIONAL CHARGE

Refrigerant suitable for a piping length of 49 ft (15 m) is charged in
the outdoor unit at the factory.
When the piping is longer than 49 ft (15 m), additional charging is necessary.
For the additional amount, see the table below.

Between 49 ft (15 m) and 99 ft (30 m), when using a connection pipe
other than that in the table, charge additional refrigerant with 0.21 oz/
ft (20g/1 m) as the criteria.

2. ADDITIONAL MATERIALS REQUIRED FOR  INSTALLATION

A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire

(See your local electrical codes.)

C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

3. OPERATING RANGE

 

CAUTION

(1) When adding refrigerant, add the refrigerant from

the charging port at the completion of work.

(2) The maximum length of the piping is 99 ft (30

m). If the units are further apart than this, cor-
rect operation can not be guaranteed.

Name and Shape Q’ty Name and Shape Q’ty

Wall hook bracket

Remote
control
unit

Battery

Tapping screw (big)

Cloth tape

1

1

2

Remote control
unit holder

1

1

8

2

Tapping screw (small)

1

1

Drain pipe
(Reverse cycle
model only)

Insulation (Drain hose)

SELECTING THE MOUNTING
POSITION

INSTALLATION DIAGRAM OF
INDOOR AND OUTDOOR UNITS

Decide the mounting position with the customer as follows:

1. INDOOR UNIT

(1) Install the indoor unit level on a strong wall which is not subject

to vibration.

(2) The inlet and outlet ports should not be obstructed : the air should

be able to blow all over the room.

(3) Install the unit near an electric outlet or special branch circuit.
(4) Do not install the unit where it will be exposed to direct sunlight.
(5) Install the unit where connection to the outdoor unit is easy.
(6) Install the unit where the drain pipe can be easily installed.
(7) Take servicing, etc. into consideration and leave the spaces shown

in the figure. Also install the unit where the filter can be removed.

2. OUTDOOR UNIT

(1) If possible, do not install the unit where it will be exposed to di-

rect sunlight. (If necessary, install a blind that does not interfere
with the air flow.)

(2) Do not install the unit where a strong wind blows or where it is

very dusty.

(3) Do not install the unit where people pass.
(4) Take your neighbors into consideration so that they are not dis-

turbed by air blowing into their windows or by noise.

(5) Provide the space shown in the figure so that the air flow is not blocked.

Also for efficient operation, leave open three of the four direc-
tions front, rear, and both sides.

 WARNING

Install at a place that can withstand the weight of the
indoor and outdoor units and install positively so that
the units will not topple or fall.

 CAUTION

(1) Do not install where there is the danger of com-

bustible gas leakage.

(2) Do not install near heat sources.

(3) If children under 10 years old may approach the

unit, take preventive measures so that they can-
not reach the unit.

(4) Install the indoor unit on the wall where the height

from the floors more than 240 cm.

[INDOOR UNIT]

[Indoor unit piping  direction]

The piping can be connected in the 7 directions in the figure. When
the piping is connected in direction 

2

3

4

 or 

5

, cut along the

piping groove in the side of the front panel with a hacksaw.

1

 Rear

     outlet

2

 Right

outlet

3

 Bottom outlet

4

 

Left bottom
outlet

5

 Left

outlet

(Rear)

6

 Center

     outlet

Remote

 control unit

[OUTDOOR UNIT]

4”(10 cm) or over

24”(60 cm) or over

4”(10 cm) or over

12”(30 cm) or over

12”
(30 cm)
or over

Tapping

screw(small)

Remote

control unit

holder

2”(5 cm) or over

Wall hook bracket

2-1/2”(6 cm)
or over

2”(5 cm)
or over

60”(150 cm)
or over

(Wall cap)

95”(240 cm)
or over

21-1/4”(54 cm)

12-9/16”

(32 cm)

Drain hose

Outdoor
unit bottom

• Do not directly install it on

the ground, otherwise it
will cause failure.

2”(5 cm) or over

 

CAUTION

(1) When the outdoor temperature is 32

 °

F or less, do not use the accessory

drain pipe and drain cap. If the drain pipe and drain cap are used, the
drain water in the pipe may freeze in extremety cold weather.(Reverse
cycle model only)

(2) In the area with heavy snowfall, if the intake and outlet of outdoor unit

is blocked with snow, it is likely to cause of the breakdown. Please con-
struct a canopy and a pedestal or place the unit on a high stand (local
configured).

• To obtain better operation

efficiency, when the outdoor
unit is installed, be sure to
open the front and left side.

Heating Mode

About 5 to 75 °F

88 °F or less

Outdoor temperature

Indoor temperature

Indoor humidity

Cooling/Dry Mode

About 14 to 115 °F

About 64 to 90 °F

About 80% or less

Pipe length

Additional

refrigerant

66 ft (20 m)

3.5 oz (100 g)

83 ft (25 m)

9.0 oz (200 g)

99 ft (30 m)

10.5 oz (300 g)

Cut each pipe to the appropriate 12” (30 cm)
to16” (40 cm) to dampen vibration between units.

B. Foamed polyethylene insulation for copper pipes as

required to precise length of piping. Wall thickness
of the insulation should not be less than 5/16” (8 mm).

C. Use insulated copper wire for field wiring.

 

CAUTION

Check local electrical codes and regulations
before obtaining wire. Also, check any specified
instructions or limitations.

Small pipe

Large pipe

Outer diameter

Thickness

Outer diameter

Thickness

1/4”(6.35 mm)

0.031496 in

5/8”(15.88 mm)

0.03937 in

(0.8 mm)

(1.0 mm)

 CAUTION

MINIMUM CIRCUIT AMPACITY

21 A

MAXIMUM OVERCURRENT PROTECTION

25 A

(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)

Connection pipe assembly

Connection cord

Wall pipe

Decorative tape

Vinyl tape

Wall cap

Saddle

Drain hose

Tapping screws

Sealant

Name

Q’ty

1

1

1

1

1

1

1 set

1

1 set

1

7

 

Left rear
outlet

Содержание MW24C3F

Страница 1: ...unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause drippin...

Страница 2: ...trol box cover 2 Fasten the Inter unit wire harness and power supply to the conduit holder using the lock nut 3 Connect inter unit wire harness and power supply to the terminal Refer to the wiring dia...

Страница 3: ...usty 3 Do not install the unit where people pass 4 Take your neighbors into consideration so that they are not dis turbed by air blowing into their windows or by noise 5 Providethespaceshowninthefigur...

Страница 4: ...ormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage REMOTE CONTROL UNIT INSTALLATION 1 REMOTE CONTROL UNIT HOLDER...

Страница 5: ...cer CONNECTING THE PIPING CONNECTION 1 Install the outdoor unit wall cap supplied with the optional installation set or procured at the site to the wall pipe 2 Connect the outdoor unit and indoor unit...

Страница 6: ...3 way valve when the reading on the compound pressure gage becomes 0 05 0 MPa 0 5 0 kg cm2 5 Stop the operation Press the START STOP button of the remote control unit to stop the operation Press the...

Страница 7: ...4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw using a screwdriver B For strand wiring 1 Cut the wire end with a wire cutter or wire cuttin...

Страница 8: ......

Отзывы: