GENERAL
This INSTALLATION MANUAL briefly outlines where
and how to install the air conditioning system. Please
read over the entire set of instructions for the indoor
and outdoor units and make sure all accessory parts
listed are with the system before beginning.
1. TYPE OF COPPER PIPE AND INSULATION MATERIAL
Copper tubing for connectin the outdoor unit to the indoor
unit and insulation material is available for purchase locally.
When you purchase them, please specify the following.
A. Deoxidized annealed copper pipe for refrigerant piping as:
STANDARD ACCESSORIES
The following installation accessories are supplied. Use them as
required.
ELECTRICAL REQUIREMENT
Always make the air conditioner power supply a special branch cir-
cuit and provide a special switch and receptacle. Do not extend the
power cord.
The following items are necessary to install this air conditioner. (The
items are not included with the air conditioner and must be purchased
separately.)
ADDITIONAL CHARGE
Refrigerant suitable for a piping length of 49 ft (15 m) is charged in
the outdoor unit at the factory.
When the piping is longer than 49 ft (15 m), additional charging is necessary.
For the additional amount, see the table below.
Between 49 ft (15 m) and 99 ft (30 m), when using a connection pipe
other than that in the table, charge additional refrigerant with 0.21 oz/
ft (20g/1 m) as the criteria.
2. ADDITIONAL MATERIALS REQUIRED FOR INSTALLATION
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire
(See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping
3. OPERATING RANGE
CAUTION
(1) When adding refrigerant, add the refrigerant from
the charging port at the completion of work.
(2) The maximum length of the piping is 99 ft (30
m). If the units are further apart than this, cor-
rect operation can not be guaranteed.
Name and Shape Q’ty Name and Shape Q’ty
Wall hook bracket
Remote
control
unit
Battery
Tapping screw (big)
Cloth tape
1
1
2
Remote control
unit holder
1
1
8
2
Tapping screw (small)
1
1
Drain pipe
(Reverse cycle
model only)
Insulation (Drain hose)
SELECTING THE MOUNTING
POSITION
INSTALLATION DIAGRAM OF
INDOOR AND OUTDOOR UNITS
Decide the mounting position with the customer as follows:
1. INDOOR UNIT
(1) Install the indoor unit level on a strong wall which is not subject
to vibration.
(2) The inlet and outlet ports should not be obstructed : the air should
be able to blow all over the room.
(3) Install the unit near an electric outlet or special branch circuit.
(4) Do not install the unit where it will be exposed to direct sunlight.
(5) Install the unit where connection to the outdoor unit is easy.
(6) Install the unit where the drain pipe can be easily installed.
(7) Take servicing, etc. into consideration and leave the spaces shown
in the figure. Also install the unit where the filter can be removed.
2. OUTDOOR UNIT
(1) If possible, do not install the unit where it will be exposed to di-
rect sunlight. (If necessary, install a blind that does not interfere
with the air flow.)
(2) Do not install the unit where a strong wind blows or where it is
very dusty.
(3) Do not install the unit where people pass.
(4) Take your neighbors into consideration so that they are not dis-
turbed by air blowing into their windows or by noise.
(5) Provide the space shown in the figure so that the air flow is not blocked.
Also for efficient operation, leave open three of the four direc-
tions front, rear, and both sides.
WARNING
Install at a place that can withstand the weight of the
indoor and outdoor units and install positively so that
the units will not topple or fall.
CAUTION
(1) Do not install where there is the danger of com-
bustible gas leakage.
(2) Do not install near heat sources.
(3) If children under 10 years old may approach the
unit, take preventive measures so that they can-
not reach the unit.
(4) Install the indoor unit on the wall where the height
from the floors more than 240 cm.
[INDOOR UNIT]
[Indoor unit piping direction]
The piping can be connected in the 7 directions in the figure. When
the piping is connected in direction
2
,
3
,
4
or
5
, cut along the
piping groove in the side of the front panel with a hacksaw.
1
Rear
outlet
2
Right
outlet
3
Bottom outlet
4
Left bottom
outlet
5
Left
outlet
(Rear)
6
Center
outlet
Remote
control unit
[OUTDOOR UNIT]
4”(10 cm) or over
24”(60 cm) or over
4”(10 cm) or over
12”(30 cm) or over
12”
(30 cm)
or over
Tapping
screw(small)
Remote
control unit
holder
2”(5 cm) or over
Wall hook bracket
2-1/2”(6 cm)
or over
2”(5 cm)
or over
60”(150 cm)
or over
(Wall cap)
95”(240 cm)
or over
21-1/4”(54 cm)
12-9/16”
(32 cm)
Drain hose
Outdoor
unit bottom
• Do not directly install it on
the ground, otherwise it
will cause failure.
2”(5 cm) or over
CAUTION
(1) When the outdoor temperature is 32
°
F or less, do not use the accessory
drain pipe and drain cap. If the drain pipe and drain cap are used, the
drain water in the pipe may freeze in extremety cold weather.(Reverse
cycle model only)
(2) In the area with heavy snowfall, if the intake and outlet of outdoor unit
is blocked with snow, it is likely to cause of the breakdown. Please con-
struct a canopy and a pedestal or place the unit on a high stand (local
configured).
• To obtain better operation
efficiency, when the outdoor
unit is installed, be sure to
open the front and left side.
Heating Mode
About 5 to 75 °F
88 °F or less
Outdoor temperature
Indoor temperature
Indoor humidity
Cooling/Dry Mode
About 14 to 115 °F
About 64 to 90 °F
About 80% or less
Pipe length
Additional
refrigerant
66 ft (20 m)
3.5 oz (100 g)
83 ft (25 m)
9.0 oz (200 g)
99 ft (30 m)
10.5 oz (300 g)
Cut each pipe to the appropriate 12” (30 cm)
to16” (40 cm) to dampen vibration between units.
B. Foamed polyethylene insulation for copper pipes as
required to precise length of piping. Wall thickness
of the insulation should not be less than 5/16” (8 mm).
C. Use insulated copper wire for field wiring.
CAUTION
Check local electrical codes and regulations
before obtaining wire. Also, check any specified
instructions or limitations.
Small pipe
Large pipe
Outer diameter
Thickness
Outer diameter
Thickness
1/4”(6.35 mm)
0.031496 in
5/8”(15.88 mm)
0.03937 in
(0.8 mm)
(1.0 mm)
CAUTION
MINIMUM CIRCUIT AMPACITY
21 A
MAXIMUM OVERCURRENT PROTECTION
25 A
(TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER)
Connection pipe assembly
Connection cord
Wall pipe
Decorative tape
Vinyl tape
Wall cap
Saddle
Drain hose
Tapping screws
Sealant
Name
Q’ty
1
1
1
1
1
1
1 set
1
1 set
1
7
Left rear
outlet
Содержание MW24C3F
Страница 8: ......