INDOOR UNIT

CUTTING THE HOLE IN THE WALL FOR THE CONNECTING PIPING

(1) Cut a 3-1/8”(80 mm) diameter hole in the wall at the position shown in

the figure.

(2) When cutting the wall hole at the inside of the wall hook bracket, cut

the hole to a point of intersection of center marks.
When cutting the wall hole at the outside of the wall hook bracket, cut
the hole at a point of 10mm below.

(3) Cut the hole so that the outside end is lower (3/16” to 3/8” (5 to 10

mm)) than the inside end.

(4) Always align the center of the wall hole. If misaligned, water leakage

will occur.

(5) Cut the wall pipe to match the wall thickness, stick it into the wall cap,

fasten the cap with vinyl tape, and stick the pipe through the hole. (The
connection pipe is supplied in the installation set.)

(6) For left piping and right piping, cut the hole a little lower so that drain

water will flow freely.

Lower

Centering marks

Lower

3-1/8”(80 mm)
hole

3-1/8”(80 mm)
hole

Wall hook bracket

3/8” (10 mm)
or over

Fasten with
vinyl tape

(Wall cap)

(Wall pipe)

(Inside)

Wall

(Outside)

3/16” to 3/8”(5 to 10 mm)

INSTALLING THE WALL HOOK BRACKET

(1) Install the wall hook bracket so that it is correctly positioned horizon-

tally and vertically. If the wall hook bracket is tiled, water will drip to the

floor.

(2) Install the wall hook bracket so that it is strong enough to withstand

the weight of an adult.

Fasten the wall hook bracket to the wall with 6 or more screws through

the holes near the outer edge of the bracket.

Check that there is no rattle at the wall hook bracket.

 

WARNING

If the wall pipe is not used, the cord interconnecting
the indoor and outdoor units may touch metal and
cause electric leakage.

Wall hook bracket

Leveling method

Hang weight

from here.

Tapping screw
(size: large; quantity: 8)

Wall hook
bracket

String

Weight

 

CAUTION

Install the wall hook bracket horizontally and perpen-
dicularly.

FORMING THE DRAIN HOSE AND PIPE

[Rear piping, Right piping, Bottom piping]

Install the indoor unit piping in the direction of the wall hole and bind
the drain hose and pipe together with vinyl tape.

Install the piping so that the drain hose is at the bottom.

Wrap the pipes of the indoor unit that are visible from the outside with
decorative tape.

[For Left rear piping, Left piping]

Interchange the drain cap and the drain hose.

Drain cap

Indoor unit
drain hose

Remove the drain cap by pulling
at the projection at the end of
the cap with pliers, etc.

For left outlet piping, cut off the
piping outlet cutting groove
with a hacksaw.

Right piping

Bind with vinyl tape

Indoor unit drain hose
(bottom)

Pipe (top)
Rear piping

Bottom

piping

Insulation (Drain hose)

Drain hose

 CAUTION

Insert the drain hose and drain cap into the drain port, mak-
ing sure that it comes in contact with the back of the drain
port, and then mount it. If the drain hose is not connected
properly, leaking will occur.

Attach the Insulation (Drain hose) to the drain hose.

For left piping and left rear piping, align the marks on the wall
hook bracket and shape the connection pipe.

Bend the connection piping at the bend radius of 4”(100 mm) or
more and install no more than 1-3/8”(35 mm) from the wall.

After passing the indoor piping and drain hose through the wall
hole, hang the indoor unit on the hooks at the top and bottom of
the wall hook bracket.

[Installing the indoor unit]

Hang the indoor unit from the hooks at the top of the wall hook
bracket.

Insert the spacer, etc. between the indoor unit and the wall hook
bracket and separate the bottom of the indoor unit from the wall.

Indoor unit

Wall hook bracket

(Spacer)

CONNECTING THE PIPING

CONNECTION

(1) Install the outdoor unit wall cap (supplied with the optional

installation set or procured at the site) to the wall pipe.

(2) Connect the outdoor unit and indoor unit piping.
(3) After matching the center of the flare surface and tightening

the nut hand tight, tighten the nut to the specified tightening
torque with a torque wrench.

FLARING

(1) Cut the connection pipe to the

necessary length with a pipe cut-
ter.

(2) Hold the pipe downward so that

cuttings will not enter the pipe
and remove the burrs.

(3) Insert the flare nut onto the pipe

and flare the pipe with a flaring
tool.

Insert the flare nut (always use the
flare nut attached to the indoor and
outdoor units respectively) onto the
pipe and perform the flare process-
ing with a flare tool.
Use the special R410A  flare tool,
or the conv-entional (for R22) flare
tool.
When using the conventional flare
tool, always use an allowance ad-
justment gauge and secure the A di-
mension shown in the table.

BENDING PIPES

(1) When bending the pipe, be careful not to crush it.
(2) To prevent breaking of the pipe, avoid sharp bends.

Bend the pipe with a radius of curvature of 6” (150 mm) or
over.

(3) If the copper pipe is bend the pipe or pulled to often, it will

become stiff.
Do not bend the pipes more than three times at one place.

Tighten with two wrenches.

Torque
wrench

Wrench (fixed)

Flare nut

Indoor unit pipe

Connection pipe

To prevent gas leakage, coat the flare
surface with refrigerator oil.

 

CAUTION

(1) Fasten a flare nut with a torque wrench as instructed in this manual. If

fastened too tight, the flare nut may be broken after a long period of time
and cause a leakage of refrigerant.

(2) During installation, make sure that the refrigerant pipe is attached firmly

before you run the compressor. Do not operate the compressor under the
condition of refrigerant piping not attached properly with 2-way or 3-way
valve open. This may cause abnormal pressure in the refrigeration cycle
that leads to breakage and even injury.

A (mm)

Pipe outside diameter

Pipe outside

diameter

ø 6.35 mm (1/4”)

ø 15.88 mm (5/8”)

Flash tool for

R410A, clutch type

0 to 0.5

0 to 0.5

Conventional (R22) flare tool

Clutch type

1.0 to 1.5

1.0 to 1.5

Wing nut type

1.5 to 2.0

1.5 to 2.0

Flare nut tightening torque and L dimension

Flare nut

1/4” (6.35 mm) dia.

5/8” (15.88 mm) dia.

Tightening torque

11.8 to 13.3 ft•lbs

(160 to 180 kgf•cm)

46.5  to 55.3 ft•lbs

(630 to 750 kgf•cm)

L dimension

1.4  to  1.7mm

2.2  to  2.4mm

A

Check if [L] is flared uniformly
and is not cracked or scratched.

Die

Pipe

 

CAUTION

 

CAUTION

(1)

  

In order to align the drain hose and drain cap, be
sure to insert securely and vertically. Incline inser-
tion will cause water leakage.

(2)

  

When inserting, be sure not to attach any material

besides water. If any other material is attached, it
will cause deterioration and water leakage.

(3)

  

After removing drain hose, be sure not to forget

mounting drain cap.

(4)

  

 Be sure to fix the drain hose with tape to the bottom
of piping.

(5)

  

Prevent drain water frozen under low tempera-

ture environment.

When installing indoor unit's drain hose outdoors, necessary
measure for frost protection should be taken to prevent drain

water frozen.

•  Under low temperature environment (when outdoor tem-

perature under 32 °F), after cooling operation is executed,
water in the drain hose could be frozen.
Once drain water is frozen, the drain hose will be blocked
and water leakage may be resulted for indoor unit.

Connection piping

Small piping

Wall hook
bracket

Alignment marks

Large piping

After hooking the indoor unit to the top hook, hook the fittings of the indoor
unit to the two bottom hooks while lowering the unit and pushing it against
the wall.

Top hooks

Indoor unit

(Fitting)

Bottom hooks

Wall hook
bracket

Содержание MW24C3F

Страница 1: ...unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause drippin...

Страница 2: ...trol box cover 2 Fasten the Inter unit wire harness and power supply to the conduit holder using the lock nut 3 Connect inter unit wire harness and power supply to the terminal Refer to the wiring dia...

Страница 3: ...usty 3 Do not install the unit where people pass 4 Take your neighbors into consideration so that they are not dis turbed by air blowing into their windows or by noise 5 Providethespaceshowninthefigur...

Страница 4: ...ormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage REMOTE CONTROL UNIT INSTALLATION 1 REMOTE CONTROL UNIT HOLDER...

Страница 5: ...cer CONNECTING THE PIPING CONNECTION 1 Install the outdoor unit wall cap supplied with the optional installation set or procured at the site to the wall pipe 2 Connect the outdoor unit and indoor unit...

Страница 6: ...3 way valve when the reading on the compound pressure gage becomes 0 05 0 MPa 0 5 0 kg cm2 5 Stop the operation Press the START STOP button of the remote control unit to stop the operation Press the...

Страница 7: ...4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw using a screwdriver B For strand wiring 1 Cut the wire end with a wire cutter or wire cuttin...

Страница 8: ......

Отзывы: