32
PB
OPERATION
9-12k Sequence of Operation
L
A
B
C
D
rotate to position D. Under other state, the horizontal louver will rotate to vain position L. If the swing function
is set when starting the unit, the horizontal louver will swing between position L and position D. There are
7 states for the louver: in Position L, Position A, Position B, Position C, Position D, and swing between Position
Land position D, stop in any position between Position L and position D. When the unit is turned off, the louver
will stay in position 0. The swing is available only when the swing function is set and the indoor fan is running.
Note: When position L to B, position A to C, and position B and D is set, the horizontal louver will swing between
position L to D. L<------>A<------>B<------>C<------>D
(8)Sleep Function
Sleeping mode is available only in cooling and heating modes;
Cooling mode: at the base of initial set temperature by remote controller, the set temperature will increase automatically
according to set point within several hours after setting sleep function.
Heating mode: at the base of initial set temperature by remote controller, the set temperature will decrease automatically according to
Set point within several hours after setting sleep function.
(9)Timer Function
0(00)
The main board has general timer function and clock function. The timer function can be selected by remote controller with different
function
1.General timer: Timer accuracy is +/- 60 seconds
Timer on: after setting timer on, the unit will run at setting time according to the original setting mode. The timing interval is 0.5 hour, and
the setting range is 0.5-24hours.
Timer off: the timer off function can be set when the unit is on. When the setting time for timer off is reached, the unit will stop. The
timing interval is 0.5 hour, and the setting range is 0.5-24 hours.
2.Clock:Start of stop at a specific time. Accuracy is +/- 60 seconds. For example; timer on at 8:00 a.m., timer off at 17:30 p.m.
Timer on: if the timer on function is set when the system is on, the system will run. If the timer on function is set when the
system is off, the system will start running in the previously set mode when the setting time is reached.
Timer off: if the timer off function is set when the system is off, the system will keep off even though the setting time is reached. If the
timer off function is set when the system is on, the system will stop running when the setting time is reached.
Timer modification: when the system is in timer state, start or stop of the unit can be set via remote ON/OFF button and the timer
can be reset. The system runs according to the latest setting state.
When both the timer on and timer off are set: the system runs according to the current mode setting. When the inputted time is reached,
the unit will start and stop running. In that case, the unit will run according to the previously setting mode when the setting time for timer
on is reached. The unit will stop running while the setting time for timer off is reached.
If the setting time for timer on and timer off is the same, the unit will stop running no matter what the current state is.
(10)Auto-Restart Function
The following settings are stored in the unit's EEPROM in the event of a power loss and Auto-Restart is active:
Mode, up and down swing, light, setting temperature, setting fan speed, general timer (not clock), Fahrenheit/ Celsius. After
de-energized, the unit can run according to internal memory once power is restored. If the time function is not set in the last remote control
command or previously before power loss, the system will run according to the last selected mode. If the timer function is set control before
it is de-energized, the system will memorize the inputted timer setting. The setting time is recalculated once power is restored to the unit.
If the timer function is set and the setting time is reached before the unit is de-energized, the unit will run according to the previous running
mode after power is restored, but the timer function will terminate and the clock will not be memorized.
(11)Turbo Function
In cooling and heating mode (not available in auto, dehumidify, fan mode), press the Turbo the fan speed displayed super high
speed in the remote controller and the indoor fan rotates at super high speed.
(12)Dry Function
When the indoor fan motor is running, the Dry function is set by pressing remote controller.
Содержание MRM09Y1J
Страница 8: ...8 INTRODUCTION MWM09Y1J MWM12Y1J Figure 101 Indoor Units MWM18Y3J MWM24Y3J MWM36Y3J...
Страница 37: ...37 OPERATION 18 24kSequenceofOperation...
Страница 38: ...38 OPERATION 18 24k Sequence of Operation O o 0 C L A B C D 1 1 4...
Страница 39: ...39 OPERATION 18 24k Sequence of Operation...
Страница 40: ...40 OPERATION 18 24k Sequence of Operation...
Страница 41: ...41 OPERATION 18 24k Sequence of Operation...
Страница 47: ...47 INSTALLATION...
Страница 48: ...48 INSTALLATION Installation Tools...
Страница 95: ...95 TROUBLESHOOTING Malfunction of IDU Fan Motor U8 Service Manual No Start End...
Страница 113: ...113 WIRING DIAGRAMS Figure 804 36K Indoor Unit Wiring Diagrams Figure 803 24K Indoor Unit Wiring Diagram 6361000043101...
Страница 116: ...116 FIgure 901 PARTS CATALOG Indoor Unit MWM09Y1J MWM12Y1J MWM09Y1J MWM12Y1J...
Страница 118: ...118 FIgure 902 PARTS CATALOG Indoor Unit MWM18Y3J MWM24Y3J...
Страница 123: ...123 FIgure 904 PARTS CATALOG Outdoor Unit MRM09Y1J MRM12Y1J MRM09Y1J MRM12Y1J...
Страница 126: ...126 PARTS CATALOG Outdoor Unit MRM18Y3J FIgure 905...
Страница 128: ...128 PARTS CATALOG Outdoor Unit MRM24Y3J FIgure 906...
Страница 130: ...130 PARTS CATALOG Outdoor Unit MRMY36J FIgure 907 2 9 10 18 20 21 11 12 14 15 22 23 26 27 32 34 4 1...