background image

3

EV

APORA

T

OR AIR 

TEMP

. DEG. F

EV

APORA

T

OR 

TEMP

. DEG. F

CONDENSER 

TEMP

.

DEG. F

Discharge 

T

emp

Suction 

T

emp

Liquid 

T

emp

Super 

Heat

Sub-

Cooling

OPERA

TING 

PRESSURES

ELECTRICAL

 RA

TINGS

R-22 

REF

.

Evap 

CFM

Motor 

RPM

BREAKER 

FUSE

Discharge 

Air

T

emp. 

Drop F

.

E(in)

E(out)

Suction

Discharge

Amps 

Cool

Amps 

Heat

Locked 

Rotor 

Amps

Charge 

in OZ.

60 Hertz 

Amps

60 Hz Models

SH15L30-B

54

26

52

56

206

129

61

108

16

98

76

258

8.2

-

-

28.5

363

1100

15

SH20L30-B

46

34

46

46

125

196

52

97

8

2

8

7

5

271

10.1

-

-

39.0

357

1100

20

Due t

o c

on

tinuing eng

ine

er

ing r

ese

ar

ch and t

echno

log

y, 

sp

ec

ific

at

ions ar

e subje

ct t

o chang

e w

ith

ou

t no

tic

e.

Manu

fa

ct

ur

ed

 under U

.S. D

esig

n Pa

ten

t DE

S 36

8, 30

6 de

co

ra

tive f

ron

t; U

tili

ty Pa

ten

t 5

, 622

, 05

8

M

AX

IMUM ou

td

oo

r ambien

t op

er

at

ing t

emp

er

at

ur

e is 1

30

°F (

54

°C

).

M

AX

IMUM T

EMPE

RA

TURE R

AT

IN

G F

OR CL

AS

S I, DI

VI

SION 2

, G

RO

UP

S A

,B

,C,D

Model

Dim

e

ns

ions

 (

Inches

)

Windo

w

 Wid

th

 

(I

n

c

h

e

s

)

Thr

u

-T

h

e

-W

all

 

Fi

n

is

h

e

d

 H

o

le

 

(I

n

c

h

e

s

)

C

ir

c

u

it R

a

ti

n

g

 

B

re

a

k

e

r o

T - D F

u

s

e

We

ig

h

(L

b

s

.)

He

ig

h

t

Width

Depth

 

Ov

e

ra

ll

Depth

 

Hood

 to

 

Louv

er

s

Minimum

Ext

e

n

s

io

n

 

Into

 

Ro

o

m

Minimum

 

Ext

e

n

s

io

n

 

O

u

ts

id

e

M

in

.

M

a

x

.

H

e

ig

h

t

W

id

th

V

o

lt

s - A

m

p

s

N

e

t

S

h

ip

p

in

g

SH

1

5

L3

0

1

5

 

15

/

16

25

 

15

/

16

27

 

3

/

8

3

/

16

1

/

16

16 

15

/

16

27

 

7

/

8

42

16

 

3

/

16

26

 

3

/

16

250V - 15A

140

152

S

H

2

0

L

3

0

17 

15

/

16

25

 

15

/

16

27

 

3

/

8

3

/

16

1

/

16

16 

15

/

16

27

 

7

/

8

42

18

 

3

/

16

26

 

3

/

16

250V - 15A

166

179

Inst

alla

ti

on

 Infor

m

a

tion

Pr

o

d

u

c

t S

p

e

c

if

ic

at

io

ns

Model

C

o

o

li

n

g C

a

p

a

c

it

y

 

E

le

c

tr

ic

a

l C

h

a

ra

c

te

ri

s

ti

c

s (6

0 H

e

rt

z)

E

n

e

rg

y

 

Ef

fi cienc

y

 

R

a

tio

 AHAM

Mois

ture

Re

m

o

v

a

Air

 Direc

tion 

Cont

rol

s

Ro

o

m

 S

id

e

 A

ir

 

C

irculat

ion

(B

T

U

/Hr

.-

 AHAM

)

V

o

lt

s

 R

a

ted

Am

ps

 

AHAM

W

at

ts

EER 

(P

in

ts

/ H

r.

)

 C

F

M

SH

1

5

L3

0

1

5

0

0

0

/1

5

0

0

0

23

0/20

8

7.9/8.

7

1

7

6

5

/1

7

6

5

8

.5

/8.

5

4

.0

8

-w

a

y

3

7

5

SH20

L3

0

1

9

8

0

0

/1

9

5

0

0

23

0/20

8

1

0

.0/

1

0

.9

2

2

0

0

/2

1

6

7

9

.0/

9

.0

5.

7

8

-w

a

y

3

7

5

P

e

rf

o

rm

a

n

c

e D

a

ta

: Cool

in

g

OPERA

TING TEMPERA

TURE CODE T3B

Содержание HAZARDGARD SH15L30-B

Страница 1: ...SH15L30 B SH20L30 B HG SVC PRTS 07 3 07 Room Air Conditioners 60 Hz Models 2007 Service Parts Manual...

Страница 2: ...ntrol Switch 5 Run Capacitor 5 Thermostat 5 Low Ambient Bypass Valve 6 Sealed Refrigeration System Repairs 6 Hermetic Component Replacement 7 Special Procedure in the case of Compressor Motor Burn Out...

Страница 3: ...TING FOR CLASS I DIVISION 2 GROUPS A B C D Model Dimensions Inches Window Width Inches Thru The Wall Finished Hole Inches Circuit Rating Breaker or T D Fuse Weight Lbs Height Width Depth Overall Depth...

Страница 4: ...hell of the compressor continuity grounded motor replace compressor 5 Should continuity exist between terminals R and S but not between terminals C and S and C and R the internal overload may be open...

Страница 5: ...can be used for each motor or a dual rated capacitor can be used for both The capacitor s primary function is to reduce the line current while greatly improving the torque characteristics of a motor...

Страница 6: ...ressure reaches 50 psig This pressure setting cannot be altered The system can be operated at outdoor temperatures as low as 45 F before the evaporator coil will begin to accumulate frost To determine...

Страница 7: ...pump to the high side and low side of the system with deep vacuum hoses or copper tubing Do not use regular hoses 10 Evacuate the system to an absolute holding pressure of 200 microns or less 12 Resta...

Страница 8: ...ive fan motor Test and replace if inoperative COMPRESSOR RUNS CONTINUALLY DOES NOT CYCLE OFF Excessive heat load Test cooling performance of unit Unit undersized Restriction in line Check for partiall...

Страница 9: ...SOR DOES NOT START FAN MOTOR RUNS Thermostat contacts not closing Check continuity of thermostat at coldest setting Jump contacts if compressor runs replace thermostat Low voltage supply Check for nam...

Страница 10: ...blade and blower wheel clearance Compressor vibrating Check for deteriorated compressor grommets or missing mounting parts Loose cabinet parts improperly mounted components tubing rubbing Adjust and t...

Страница 11: ...11 WIRING DIAGRAM MODELS SH15L30 B and SH20L30 B...

Страница 12: ...12 HAZARDGARD CABINET PARTS...

Страница 13: ...13 HAZARDGARD CHASSIS PARTS...

Страница 14: ...1 399 RELAY SOLID STATE 61108800 2 2 399 6 THERMOSTAT 61822502 1 1 120 7 CAPACITOR 20 7 5 440 V 61080546 1 150 7 CAPACITOR 25 7 5 440 V 61080547 1 150 HARNESS WIRE COMP 61821308 1 1 399 REFRIGERATION...

Страница 15: ...4905 1 743 30 SCROLL 61817505 1 743 32 BASE PAN 61803444 1 1 730 34 BOLT COMP MOUNT 91400400 3 3 791 35 PLENUM ASSEMBLY 61831006 1 1 753 36 OUTER SHELL 61825708 1 770 36 OUTER SHELL 61825709 1 770 37...

Страница 16: ...rranty period providing the unit is returned to an authorized Friedrich Repair Station located within the Continental United States The Friedrich warranty does not cover 1 Any charges for removal tran...

Отзывы: