22
PB
OPERATION
Function and Control
Advanced Settings Example
Setting target: d0(C), d1(r), d2(30
°
C), d3(18
°
C), d4(-1
°
C), d5(1).
Step 1: hold [HEAT] and [FAN SPEED] two keys at the same time continuously for 5 seconds.
Display:’d0’’
Step 2: short press [HEAT] key.
Display: ‘F’
Step 3: short press [+] or [-] key.
Display: ‘C’ (setting d0 has finished)
Step 4: short press [HEAT] key.
Display:’d0’
Step 5: short press [+] key.
Display:’d1’
Step 6: short press [HEAT] key.
Display: ‘P’
Step 7: short press [+] or [-] key.
Display: ‘r’ (setting d1 has finished)
Step 8: short press [HEAT] key.
Display:’d1’
Step 9: short press [+] key.
Display:’d2’
Step10: short press [HEAT] key.
Display:’32’
Step11: short press [-] key twice.
Display:’30’ (setting d2 has finished)
Step12: short press [HEAT] key.
Display:’d2’
Step13: short press [+] key.
Display:’d3’
Step14: short press [HEAT] key.
Display:’16’
Step15: short press [+] key twice.
Display:’18’ (setting d3 has finished)
Setp16: short press [HEAT] key.
Display:’d3’
Step17: short press [+] key.
Display:’d4’
Setp18: short press [HEAT] key.
Display:’0’
Memory Function
The unit will run the same status from the last moment before power down.
FD Control (front-desk control) & 24V REMOTE THERMOSTAT
The unit can be turned ON/OFF by front desk control switch. The control terminal is located on the remote thermostat
interface, FD.