background image

Friedrich Air Conditioning Company 

P.O. Box 1540

San Antonio, TX 78295 

210.357.4400

www.friedrich.com

ROOM AIR CONDITIONERS 

LIMITED WARRANTY

FIRST YEAR 

ANY PART:

  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from 

date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible
for service.  Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service
Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive
remedy within twelve months from the date of the original purchase. 

SECOND THROUGH FIFTH YEAR

SEALED REFRIGERANT SYSTEM:

  If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser 

coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in 
your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, 
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System;  

PROVIDED

 FRIEDRICH will 

not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the
Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System.  All such cost will be the 
sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the 
original purchase. 

APPLICABILITY AND LIMITATIONS:

  This warranty is applicable only to units retained within the Fifty States of the U.S.A., District 

of Columbia, and Canada.  This warranty is not applicable to: 

 

1.    Air filters or fuses. 

 

2.    Products on which the model and serial numbers have been removed. 

 

3.   Products which have defects or damage which results from improper installation, wiring, electrical current 

characteristics, or maintenance;  or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication 
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by  war, 
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God. 

OBTAINING WARRANTY PERFORMANCE:

  Service will be provided by the

 FRIEDRICH Authorized Dealer or Service

Organization

 in your area.  They are listed in the Yellow Pages.  If assistance is required in obtaining warranty performance, write 

to:  Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540. 

LIMITATIONS:  THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES.  Anything in the warranty 
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY 
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.  MANUFACTURER EXPRESSLY DISCLAIMS AND 
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR 
IMPLIED WARRANTY. 

NOTE:

  Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of 

consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. 

OTHER:

  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

PROOF OF PURCHASE:

  Owner must provide proof of purchase in order to receive any warranty related services. 

All service calls for explaining the operation of this product will be the sole responsibility of the consumer. 

All warranty service must be provided by an 

Authorized FRIEDRICH Service Agency

, unless authorized by FRIEDRICH prior to 

repairs being made. 

(10-04)

Friedrich Air Conditioning Co.
Post Offi ce Box 1540 • San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212
(210) 357-4400 • FAX (210) 357-4480
www.friedrich.com

CP-14-18-24-Svc-Prts-07 (3-07)

Содержание CP14-18-24 CP14N10

Страница 1: ...Service Parts Manual 2007 Compact Programmable Models CP14N10 CP18N30 CP24N30 CP 14 18 24 Svc Prts 07 3 07...

Страница 2: ...ion and repair and who is equipped with the proper tools and test instruments Installation or repairs made by unqualified persons can result in hazards subjecting the unqualified person making such re...

Страница 3: ...15 59 15 59 15 59 Fan Motor Speed rpm H M L 900 780 730 900 780 730 1000 900 800 Output of Fan Motor W 200 200 190 Fan Motor RLA A 3 1 45 1 35 Fan Motor Capacitor uF 15 MFD 7 MFD 7 MFD Permissible Exc...

Страница 4: ...4 Outer Component Identification Models CP14N10 CP18N30 CP24N30 Cabinet Air inlet louver Front grille Power cord Control panel cover Front intake grille Air filter behind front intake grille...

Страница 5: ...5 Installation Dimensions Models CP14N10 CP18N30 CP24N30 Top View Fence obstruction Over 2 Over 1 Over 1 Wall Or window Front View Side View Ceiling Over 1 Over 1 25 98 16 85 Less than 8 66 Over 2...

Страница 6: ...6 CP24N30 CP18N30 CP14N10 Wiring Diagrams...

Страница 7: ...OMPONENTS Thermostat Used to maintain the specified room side comfort level Capacitor Reduces line current and steadies the voltage supply while greatly improving the torque characteristics of the fan...

Страница 8: ...consuming if not in some cases entirelyimpossible Therefrigerationsystemusesfourbasic principles laws in its operation they are as follows 1 Heat always flows from a warmer body to a cooler body 2 Hea...

Страница 9: ...leaks found 8 Reduce the system to zero gauge pressure 9 Connect vacuum pump to high side and low side of system with deep vacuum hoses or copper tubing Do not use regular hoses 10 Evacuate system to...

Страница 10: ...pressor eventually causing a mechanical failure within the compressor This mechanical failure can manifest itself as valve failure bearing failure and or other mechanical failure The specific type of...

Страница 11: ...10 to 15 minutes check the gauge pressures Gauges connected to system with an undercharge will have low head pressures and substantially low suction pressures UNDERCHARGED REFRIGERANT SYSTEMS NOTE He...

Страница 12: ...considerably less than normal as the compressor is running in a deep vacuum no load Much of the area of the condenser will be relatively cool since most or all of the liquid refrigerant will be stored...

Страница 13: ...perative Broken loose or incorrect wiring Refer to applicable wiring diagram Open capacitor Test capacitor replace if inoperative Fan speed switch open Test switch replace if inoperative Inoperative f...

Страница 14: ...emp differential delta T across coil Touch test coil return bends for same temp Test for low running current Problem Possible Cause Action Compressor runs continually does not cycle off Excessive heat...

Страница 15: ...stat terminals to check if unit operates If unit operates replace t stat Loose or broken parts in t stat Check as above Incorrect wiring Refer to appropriate wiring diagram Problem Possible Cause Acti...

Страница 16: ...ntial too narrow Replace t stat Plenum gasket not sealing allowing discharge air to short cycle t stat Check gasket Reposition or replace as needed Restricted coil or dirty filter Clean advise custome...

Страница 17: ...ontacts remain closed between terminals 2 3 of the defrost control after preselected time interval has passed replace control Defrost control bulb removed from or not making good coil contact Reinstal...

Страница 18: ...h Problem Possible Cause Action Cooling adequate but heating insufficient Heating capillary tube partially restricted Check for partially starved outer coil Replace heating capillary tube Check valve...

Страница 19: ...19 Components Model CP14N10...

Страница 20: ...67700205 15 Washer 4 1 67700158 16 Screw ST4 2X22 4 67700153 17 Top Rail Assy 1 67700206 18 Screw ST4X10 4 67700152 19 Condenser Assy 1 67700207 20 Nut with Washer M10 1 67700157 21 Washer 10 1 67700...

Страница 21: ...10 120V 1 67700220 50 Transformer 41X26 5C 1 67700221 51 Capacitor clamp 1 67700114 52 Main PCB M2A91J 1 67700222 53 Electric box 1 67700136 54 Isolation Washer D 1 67700223 55 Wire Clamp 1 67700160 5...

Страница 22: ...7700150 15 Washer 4 1 67700158 16 Self threading Screw ST4 2x22 6 67700153 17 Top Rail 1 67700134 18 Self threading Screw with Gasket ST4X10 4 67700152 19 Condenser Assy 1 67700104 20 Nut with Washer...

Страница 23: ...200V 240V TUV 1 67700147 50 Power Transformer 41X26 5F 1 67700146 51 Capacitor Clamp 1 67700114 52 Electric box 1 67700136 53 Main PCB J25713J 1 67700142 54 Fixed Clamp 1 67700160 55 Power cord 1 677...

Страница 24: ...24 Components Model CP24N30...

Страница 25: ...er 4 1 67700158 16 Screw ST4 2X22 4 67700153 17 Top Rail Assy 1 67700206 18 Screw ST4X10 4 67700152 19 Condenser Assy 1 67700239 20 Nut with Washer M10 1 67700157 21 Washer 10 1 67700159 22 Fan Blade...

Страница 26: ...ransformer 41X26 5C 1 67700247 51 Capacitor clamp 1 67700114 52 Main PCB M2A91J 1 67700248 53 Electric box 1 67700136 54 Isolation Washer D 1 67700223 55 Wire Clamp 1 67700160 56 Power cord 1 67700249...

Страница 27: ...been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or maintenance or caused by accident misuse or abuse fire flood...

Страница 28: ...Prts 07 3 07 Friedrich Air Conditioning Co Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com Print...

Отзывы: