Error
Code
Description
Error Indication
Indoor
Operation
Indoor
Outdoor
1
Indoor Temperature Sensor Error
- Suction Sensor open/short
- Indoor Pipe Sensor open/short
●
-
Operation
2
Outdoor Temperature Sensor Error
- Suction Sensor open/short
- Outdoor Pipe Sensor open/short
●
●
Operation
3
Humidity Temperature Sensor Error
- Humidity Sensor short
●
●
Operation
4
Heat Sink Temperature Sensor Error
- Temperature Sensor open/short
- Compressor-off Temperature ≤ Heat Sink Temperature
●
●
Operation
5
Poor Communication(Indoor <-> Outdoor Unit)
- The communication is stopped for more than 2 minutes.
●
●
Stop
6
DC Peak Error
- DC Peak occurred
●
●
Shutdown
7
CT Error
- CT detected
●
●
Shutdown
8
Indoor Unit Fan Lock Error
- Fan Lock occurred (BLDC Motor)
●
-
Stop
9
Outdoor Unit Fan Lock Error
- Fan Lock occurred(BLDC Motor)
●
●
Stop
10
Compressor Dome Temperature Error
- Discharge Pipe Sensor open/short
- Compressor-off Temperature ≤ Discharge Pipe Temperature
●
●
Operation
12
EEPROM Error
- EEPROM Check sum Error
-
●
Operation
13
PSC Error
- PSC Fault Error
-
●
Operation
14
Compressor Phase Current Error
- Phase over-current occurred
-
●
Operation
Part 4 Trouble Shooting
- 36 -
■
Old Model Error
Ex) Error Code 6 : DC Peak Error
Ex) Error Code 13 : PSC Error
6times
6times
3sec
1time
3times
1time
3sec
3times
Содержание AS - W126BMS0
Страница 3: ...3 1 Safety Precautions 4 2 Nomenclature 7 Part 1 General Information...
Страница 16: ...16 Part 3 Test Run 1 Check before Test Run 17 2 Test Run Flow chart 18 3 Test Run Detail 19...
Страница 37: ...Part 4 Trouble Shooting 37 Troubleshooting Guide Indoor Unit...
Страница 41: ...Part 4 Trouble Shooting 41 verify with hands verify with hands...
Страница 44: ...Part 4 Trouble Shooting 44 Case of field defect IPM Over Current Limit Bending Folding SVC Valve close...
Страница 46: ...Part 4 Trouble Shooting 46 3 CH23 DC Link Low Voltage Error...
Страница 51: ...Part 4 Trouble Shooting 51 8 CH40 CT Sensor Error Open Short Tester Tester...
Страница 52: ...Part 4 Trouble Shooting 52 9 CH41 44 45 65 Inv D Pipe Outdoor Inlet Cond Pipe Heat sink Sensor Error...
Страница 53: ...Part 4 Trouble Shooting 53 10 CH53 Outdoor Unit Indoor Unit Communication Error...
Страница 56: ...Part 4 Trouble Shooting 56 13 CH62 Heat Sink Overheat Error...
Страница 57: ...Part 4 Trouble Shooting 57 14 CH67 Outdoor BLDC Fan Lock Error Case of field defect BLDC Fan Motor short...
Страница 59: ...Part 4 Trouble Shooting 59 Resistance between the lines of each 1 5 2 1 5 2 1 5 2 U V V W W U...
Страница 61: ...Part 4 Trouble Shooting 61 3 CH23 DC Link Low Voltage Error...
Страница 66: ...Part 4 Trouble Shooting 66 8 CH41 44 45 65 Inv D Pipe Outdoor Inlet Cond Pipe Heat sink Sensor Error...
Страница 67: ...Part 4 Trouble Shooting 67 9 CH53 Outdoor Unit Indoor Unit Communication Error...
Страница 68: ...Part 4 Trouble Shooting 68 10 CH60 Outdoor Unit PCB EEPROM Error...
Страница 71: ...Part 4 Trouble Shooting 71 13 CH67 Outdoor BLDC Fan Lock Error...
Страница 72: ...P No MFL41161608...