![FRICON LSMR120M1A Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/fricon/lsmr120m1a/lsmr120m1a_operation-and-maintenance_2332542050.webp)
SMR
English
50
•
You can only clean the inside of the lid with a soft cotton cloth moistened with
the following solution: 90% distilled water + 10% isopropyl alcohol and clean the
entire area. Cleaning products can destroy the coating.
•
The outer part of the lid can be cleaned with normal cleaning products.
NOTES:
•
Do not use hot water on glass doors while they are cold: the temperature
difference might break them.
•
Do not remove fixed parts for cleaning. If necessary, they must be cleaned by
qualified personnel.
•
Do not use hot water on glass doors while they are cold: the temperature
difference might break them.
Component Replacement
:
If any component of the equipment is damaged, it must be replaced by personnel
qualified for this task.
10. Problem Resolution Guide
10.1. The equipment does not work
•
Check if there is electrical current.
•
Check if the plug is properly inserted in the source outlet and if the voltage and
frequency are appropriate for operation.
10.2. Unsatisfactory temperature
•
Check if the equipment has been connected long enough to have reached
operation temperature.
•
Check if the appliance is not near heat sources.
•
Check if the doors are properly closed.
•
Check the temperature regulation.
•
Check if the products do not exceed the load limit.
•
Check if the room and defrosting probe thermostats are turned on correctly.
•
Check if the condenser fan is working.
•
Check if the condenser is unobstructed.
10.3. Very noisy equipment
•
Check if the equipment is placed on a leveled surface.
•
Check if the vents are unobstructed.
•
Check if the screws and nuts are perfectly fastened.
•
Check if the cooling fan has any problems / does not work properly.
•
Check if the compressor has any problems / does not work properly.
•
Check if any of the condenser’s support parts are loose / broken.
10.4. Light does not work
•
Check that the light has power.
•
Check that the light has been turned off by the timer (Carel controller).
Содержание LSMR120M1A
Страница 1: ......
Страница 202: ...202 Declara o de conformidade linha SMR...
Страница 203: ...203 Declara o de conformidade linha LSMR...
Страница 204: ...Mod 144 2 Mod 144 2...