background image

IHC

8

EN

Maintenance 

 The power supply to the unit must be 
disconnected during all service, repair and 
maintenance work.  

The unit has no moving parts so the 

maintenance requirement is small, but it 
must be kept clean and free from dust and 
dirt. If the reflector is not clean the thermal 
radiation from the unit will decrease and the 
heater will become hotter. A large amount of 
dirt can cause overheating. 

The surface of the reflector is sensitive and 

must be cleaned with care. If the reflector 
is dirty it must be cleaned or replaced by a 
specialist.  

Residual current circuit breaker

When the installation is protected by means 
of a residual current circuit breaker, which 
trips when the appliance is connected, 
this may be due to moisture in the heating 
element. When an appliance containing a 
heater element has not been used for a long 
period or stored in a damp environment, 
moisture can enter the element. 

This should not be seen as a fault, but is 

simply rectified by connecting the appliance 
to the main supply via a socket without a 
safety cut-out, so that the moisture can be 
eliminated from the element. The drying 
time can vary from a few hours to a few days. 
As a preventive measure, the unit should 
occasionally be run for a short time when it is 
not being used for extended periods of time. 

Packaging

Packaging materials are chosen with 
consideration to environment and are 
therefore recyclable.  
 

Handling of product at end of working life

This product may contain substances 
necessary for functionality of product but 
potentially dangerous for the environment. 
The product should not be disposed 
mixed with general household waste but 
delivered to a designated collection point for 

environmental recycling. Please contact local 
authority for further details of your nearest 
designated collection point.  
 

Safety  

• 

For all installations of electrically heated 
products should a residual current circuit 
breaker 300 mA for fire protection be used.

 

• 

The unit must not be fully or partially 
covered as overheating can result in a fire 
risk! 

• 

The unit must not be placed directly under 
fixed wall sockets! 

• 

The unit must not be used if the unit or the 
cord is damaged. Risk of injury! 

 

• 

The heater is equipped with a protective 
grille to prevent contact or to prevent 
large objects from touching the hot lamp. 
The unit must not be used without this 
protective grille. 

• 

The cable and plug must not be placed 
inside the hot radiant area. 

• 

This appliance can be used by children 
aged from 8 years and above and persons 
with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. Children 
shall not play with the appliance. Cleaning 
and user maintenance shall not be made by 
children without supervision. 

• 

Children of less than 3 years should be kept 
away unless continuously supervised. 

• 

Children aged from 3 years and less than 8 
years shall only switch on/off the appliance 
provided that it has been placed or installed 
in its intended normal operating position 
and they have been given supervision or 
instruction concerning use of the appliance 
in a safe way and understand the hazards 
involved. 

• 

Children aged from 3 years and less than 8 
years shall not plug in, regulate and clean 
the appliance or perform user maintenance.  

CAUTION — Some parts of this product can 
become very hot and cause burns. Particular 
attention has to be given where children and 
vulnerable people are present. 

10. The protective tube must be refitted to the 

cables, so that the cables are not damaged 
when the grille is fitted. 

11. Reassemble the unit again. 
See the introduction pages. 

Содержание 19603

Страница 1: ...IHC Original instructions 7 EN 9 SE 12 NO 15 FR 18 DE 22 ES 25 NL 29 IT 32 PL 35 RU 38 FI...

Страница 2: ...Texte in englischer Sprache siehe die entsprechenden Sprachseiten DE Las p ginas introductorias contienen b sicamente im genes Consulte la traducci n de los textos en ingl s que las acompa an en las...

Страница 3: ...500 676 169 160 0 9 77 147 Positioning Fig 1 The heaters should heat from at least two directions for even heating 46 5 60 115 24 8 17 5 25 5 35 Dimensions 2 3 m 1 8 2 5 m Installation height Wallbra...

Страница 4: ...IHC 4 1 3 3 4 5 2 1 Replacing the lamp Minimum mounting distance 200 180 min 30 1800 300 1000 160 500 IHE ceiling bracket Flammable material...

Страница 5: ...HXL IHT IHTW IHE IHP IHP IHT Controls 92867 IHBD3 10740 CBT IHBD3 CBT IHT See separate manual See separate manual 11884 IHUB 18050 IHE 16975 IHXH 16976 IHXL 11887 IHT 16974 IHTW 16970 IHP 92865 KLS1KS...

Страница 6: ...x load 3500W N IH IHC 1 2 3 CBT 230V L N L N IH IHC L N IH IHC L L1 L2 L3 N L N 400V3 Technical specifications Carbon infrared heater IHC IP44 Item number Type Heat output W Voltage V Amperage A Max f...

Страница 7: ...hit by thermal radiation Contact an electrician if the cord needs to be changed Note that due to the high temperatures in the heater a cord of the type H05 RN F 3G1 mm or the like should be used In t...

Страница 8: ...rther details of your nearest designated collection point Safety For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used The...

Страница 9: ...20 04 20 HH CH Main office Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local conta...

Отзывы: