070.750-IOM2 (JAN 21)
Page 4
HPS 273 ROTARY SCREW COMPRESSOR
INSTALLATION - OPERATION - MAINTENANCE
The compressor model number designates the size of the
compresso
r and its Vi configuration.
Example: HPSS 2709 A
HPSS 27 09 A
Model/series
HPS = High-pressure screw
Bearing arrangement
S = Single radial bearings (273 only)
D = Double radial bearings (273 only)
Rotor diameter
27 = 273 mm
Rotor length designation
09
10
12
Vi
configuration
A = 2.2 – 5.0
B = 1.7 – 3.0
C = 1.3 – 1.96
Rotor length ÷ diameter x 10
Rotary screw compressor serial numbers identify the
factory that the compressor was manufactured in and its
build date. They are defined by the following information:
Example:
1024 0 A 9 0000015 Z
Plant
Decade Month
Year
Global
Seq no.
Additional
Remarks
1024
0
A
9
0000015 Z
Month:
A = JAN, B = FEB, C = MAR, D = APR, E = MAY, F = JUN,
G = JUL, H = AUG, K = SEP, L = OCT, M = NOV, N = DEC
Additional Remarks:
R = Remanufactured
R1 = Rebuild
R2 = Rebuild Plus
Z = Deviation from base configuration.
show what refrigerants are
compatible with the compressor as manufactured.
Figure 2: Refrigerant nameplates
Table 1: Geometrical swept volume
HPS
rpm
HPS 2709
HPS 2712
2%
2709/2712
m
3
/h (cfm)
m
3
/h (cfm)
Lpm
1450
676 (398)
901 (530)
133/177
1750
816 (480)
640 (1088)
160/213
2950
1375 (809)
1833 (1079)
270/360
3550
1655 (974)
2206 (1298)
325/433
Note:
2% is oil flow as a percentage of swept volume.
Table 2: Compressor long-term storage log
Model
Serial no.
Compressor, motor oil
pump and refrigerant pump
shaft rotation 1 1/2 turn
Rotor
housing
charge
Charge
added
Visual
inspec-
tion
Charge
Checked by Date