Error messages:
No Text in
Signifi-
Remedy
Display cance/
Causes
02 Temperature
Ambient
Set up tent
outside range temperature if necessary.
outside
permitted
range.
03 Resistance Electrical Check
contact
outside
resistance for
firm
tolerance
of fitting
seating/dirt.
outside Maybe
clean
tolerance.
contacts, if
necessary
replace fitting.
04 Fitting winding Short circuit Replace
short circuit
in the wire
fitting,
winding of
send in
fitting. for
checks.
05 Fitting winding Current flow Check
open circuit
interrupted.
connection of
fusion plug on
fitting. If okay
replace the
fitting and send
in for checks.
06 Voltage Non Contact
outside
permitted authorized
tolerance
deviation of
service station.
fusion
voltage.
08 Mains voltage
Power
Extension
outside range voltage
cable too long
outside or
cross
permitted
section too
range during small. Check
fusion. voltage
and
connections
of generator.
09 Frequency Frequency
Check
outside range
outside
frequency
permitted
of generator
range during voltage.
fusion.