Page 21
Service Manual Multi Deck 60/100/120 / Classic Deck form 9123661 rev. 10/2015
ELECTRICAL TESTS AND SERVICE PROCEDURES
ADJUSTING DANFOSS EKC 101A THERMOSTAT (CONTINUED)
Setting internal parameters
1.
Press top key for 2 seconds. In display the first parameter appears.
2.
Select parameter with bottom or top key.
3.
Press both keys together to read out value.
4.
Change value with top or bottom key.
5.
Press both keys again to confirm. When no key is pressed after last confirmation,
system goes back to normal operation mode after 25 seconds.
Replacing of thermostat
When installing a new thermostat, always change parameter o7 first to HE. Otherwise some
other parameters cannot be changed to the desired value.
Error message on display
Er: Temperature sensor broken or wiring problem sensor.
Parameters Danfoss EKC 101A thermostat
Parameter
Description
Multi Deck MD 60, with closed shelfs
Multi Deck MD 60 + Classic Deck
Multi Deck MD60 Cuisine de France
Multi Deck MD 100
Multi Deck MD 120
Standaard value from supplier
Setpoint
°C
84
80
80
80
80
0
r1 Switching differential
°K
2
1
1
1
1
2
r2 Maximum setpoint
°C
99
99
99
99
99
50
r3 Minimum setpoint
°C
0
0
0
0
0
-60
r4 Off-set temp. sensor
°K
-10
0
0
0
0
0.0
o7 Function: Cooling/he-
ating
rE / HE
HE
HE
HE
HE
HE
rE
Содержание CLASSIC DECK HOT MERCHANDISER
Страница 2: ...Page 2 SERVICE MANUAL MULTI DECK 60 100 120 CLASSIC DECK FORM 9123661 REV 10 2015...
Страница 25: ...Page 25 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015 EXPLODED VIEWS AND PARTLISTS...
Страница 42: ...Page 42 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015...
Страница 43: ...Page 43 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015...