TROUBLESHOOTING
Page 24
Service Manual Multi Deck 60/100/120 / Classic Deck form 9123661 rev. 10/2015
Description of part
Symptoms
Possible causes
Solving: checking / action
Relay K1 (Finder relay in
older models)
Relay does not come in.
Wiring
Check the wiring
Coil malfunction
Check resistance of coil. This
should be ± 7.0KΩ
Contact burned
Check the contacts
Contactor K1
Contactor does not come in. Wiring
Check the wiring
Coil malfunction
Check resistance of the coil.
This should be ± 525Ω
No tension on one or more
phases
Bad contact
Check the contacts
Heating element
The cabinet is not reaching
the adjusted temperature
Wiring
Check the wiring
Check the power on the
element
Element malfunction
Check the current with AC
current tester. See table on
page 15
Tumble switch
Light or heating does not
switch on
Wiring
Check the wiring
Contact burned
Check the voltage on “in”-
and “output”.
Electronic ballast
Light does not switch on
Wiring
Check the wiring
Ballast malfunction
Replace ballast
PL lamp(s)
Light does not switch on
Wiring
Check the wiring
Lamp(s) broken
Replace lamp(s)
Security thermostat
The cabinet is not reaching
the adjusted temperature
Wiring
Check the wiring
Security thermostat switched
off
Reset thermostat
Security thermostat malfunc-
tion
Replace thermostat
Electronic thermostat
Display does not light up
Wiring
Check the wiring
The cabinet is not reaching
the adjusted temperature or
does not heat up at all
Loose sensor
Check sensor
Thermostat malfunction
Replace thermostat
PTC 1000 sensor
The cabinet is not reaching
the adjusted temperature or
does not heat up at all
Broken sensor
Replace sensor
Loose sensor
Check wiring
The cabinet becomes too
hot
Broken sensor
Replace sensor
Sensor shorted
Check wiring
Blower(s) on heaters
Security thermostat swit-
ched off
Wiring
Check wiring
Check voltage on blower
Blower malfunction
Check for blockage
Replace blower
Blower(s) air curtain
The cabinet is not reaching
the adjusted temperature
Wiring
Check wiring
Check the voltage on blower
Blower malfunction
Check for blockage
Replace blower
This is an analytic description for servicing and repairing all major parts of the Multi Deck 60, 100 and
120 Hot and Classic Deck Hot. It consists of 4 basic steps to recognize and solve the problems:
1. Symptoms.
2. Possible causes.
3. Solving of the problem: checking/action.
4. Replacing of parts and testing: a. Replacing is described in this service manual.
b. For testing see control locations on page 17 of this manual.
Содержание CLASSIC DECK HOT MERCHANDISER
Страница 2: ...Page 2 SERVICE MANUAL MULTI DECK 60 100 120 CLASSIC DECK FORM 9123661 REV 10 2015...
Страница 25: ...Page 25 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015 EXPLODED VIEWS AND PARTLISTS...
Страница 42: ...Page 42 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015...
Страница 43: ...Page 43 Service Manual Multi Deck 60 100 120 Classic Deck form 9123661 rev 10 2015...