FreiStil Tischlerei LUKAS 136 Скачать руководство пользователя страница 2

 

 

 

BT 2018 Lukas 136/170 – 01  

 

 

 

 

 

 

 

Version – 05/2018

 

 

- 2 - 

TABLE OF CONTENTS

 

 

1. Assembly instructions

 (for authorised sales agents only)      

    

Page 

   

 

  1.1 

Assembling the bed frame   

 

 

 

 

 

03 

   

 

  1.2 

Positioning the lifting scissors 

 

 

 

 

 

03 

   

 

   

 

Assembling the bed base 

 

 

 

 

 

04 

   

 

   

 

Connecting the cables 

 

 

 

 

 

04 

   

 

   

 

Attaching the protective guard 

 

 

 

 

04 

   

 

  1.3 

Installing the rear frame 

 

 

 

 

 

 

05 

   

 

  1.4 

Installing the doors   

 

 

 

 

 

 

05 

   

 

  1.5 

Flush bolt, patent lock and sliding rail 

 

 

 

05 

   

 

  1.6 

Transport wheels 

 

 

 

 

 

 

 

06 

   

 

  1.7 

Securing the inner doors 

 

 

 

 

 

 

06 

   

 

  1.8 

Adjusting the doors   

 

 

 

 

 

 

06 

   

 

   

   

2.   Operating instructions 

   

 

  2.1 

Intended use   

 

 

 

 

 

 

 

07 

   

 

  2.2 

Important information on operational safety 

 

 

 

07 

   

 

  2.3 

Warning notices 

 

 

 

 

 

 

 

08 

   

 

  2.4 

Lifting unit 

 

 

 

 

 

 

 

 

09 

   

 

  2.5 

Bed base 

 

 

 

 

 

 

 

 

09 

   

 

  2.6 

Manual control unit   

 

 

 

 

 

 

10 

   

 

  2.7 

Revolving doors 

 

 

 

 

 

 

 

11 

   

 

  2.8 

Transport wheels 

 

 

 

 

 

 

 

11 

   

 

  2.9 

Securing the inner doors 

 

 

 

 

 

 

11 

   

 

  2.10  Patient lifting unit 

 

 

 

 

 

 

 

11 

   

 

  2.11  Cleaning, maintenance and re-usage (spare parts list) 

 

 

12 

   

 

  2.12  Accessories   

 

 

 

 

 

 

 

12 

   

 

  2.13  Symbols 

 

 

 

 

 

 

 

 

12 

   

3.   Technical data 

   

 

 

3.1 

Bed frame 

 

 

 

 

 

 

 

 

13 

   

 

  3.2 

Lifting unit 

 

 

 

 

 

 

 

 

14 

   

 

  3.3 

Bed base 

 

 

 

 

 

 

 

 

14 

   

 

  3.4 

Motors 

 

 

 

 

 

 

 

 

14

 

   

4.   Annex

 

(for authorised sales agents only)

 

   

 

 

4.1 

General instructions   

 

 

 

 

 

 

An01 

   

 

 

4.2 

Maintenance instructions 

 

 

 

 

 

 

An02 

   

 

   

Check list 
Maintenance/safety check in accordance with § 6 of the German Medical Device 
Operator Ordinance (MPBetreibV) 

Содержание LUKAS 136

Страница 1: ...Phone 49 0 541 800 3969 0 Fax 49 0 541 800 3969 99 Email info freistil com Website www freistil com OPERATING INSTRUCTIONS Children s Therapeutic Bed LUKAS door height 136cm door height 170cm Read ca...

Страница 2: ...ng instructions 2 1 Intended use 07 2 2 Important information on operational safety 07 2 3 Warning notices 08 2 4 Lifting unit 09 2 5 Bed base 09 2 6 Manual control unit 10 2 7 Revolving doors 11 2 8...

Страница 3: ...here are stickers with arrows numbered from 1 to 4 Fig 1 Arrange the side panels the head end and the foot end according to these numbers Fig 1 Screw the side panels to the head end and foot end accor...

Страница 4: ...sition the lifting scissors according to the head end sticker in the bed frame Fig 3 Move the lifting scissors to the uppermost position Fig 4 Screw the lifting scissors onto the supporting strip usin...

Страница 5: ...rs adapter using the enclosed flat head screws 4 x 35 mm Fig 8 Fig 7 Fig 8 If present connect the cable for the dual motor to the control unit Fig 9 The control unit is located on the lifting scissors...

Страница 6: ...d end foot end of the bed frame according to the colour coding using the enclosed screws M8 x 100 mm Fig 13 Then attach the second door unit accordingly Fig 13 Insert or remove spacers betwen the door...

Страница 7: ...them opening unintentionally Fig 19 Fig 19 1 8 Adjusting the doors It is possible to correct stiff or hanging doors using a size 3 Allen key by unscrewing the support foot in the outer door hinges Tog...

Страница 8: ...ntaneous mobility or young people and adults with cognitive developmental disorders for example it An ergonomic sitting position is necessary in bed due to trunk instability Secure contact between the...

Страница 9: ...structions item 2 3 2 4 and type plate VII In the event of misuse improper use incorrect operation or incorrect assembly repair no liability will be accepted for any damage In such cases all warrantie...

Страница 10: ...the head end or the head end foot end accessories must only be used to lift and lower the upper body and legs observe the position of the patient in the bed 2 5 Bed base The lifting unit is used for t...

Страница 11: ...nabling and disabling the function keys is located on the back of the manual control unit Fig 22 Turn the key to enable and disable the manual control unit The arrow indicates the relevant position Th...

Страница 12: ...ed wooden strip Fig 25 In this case the doors are locked by turning the locking pins Fig 23 Fig 24 Fig 25 2 8 Transport wheels Caster 75 x 30mm To secure the lock press the foot lever down To release...

Страница 13: ...intenance safety checks and inspection intervals see item 4 of the ANNEX to the operating instructions Spare parts lists can be obtained from the manufacturer 2 12 Accessories Mattress not readily fla...

Страница 14: ...0 x 200 cm External dimensions 1072 x 2160 mm Bed base 1000 x 2000 mm Mattress size 1000 x 2000 mm Adjustment range of the lifting scissors 390 830 mm Bed height wheel diameter 75 mm 2260 mm Door heig...

Страница 15: ...ckrest rotary points of back section seating section upper lower leg section 94 Weight approx 20 kg User load 135 kg Safe working load 170 kg 3 4 Motors Limoss Mains voltage frequency 230 volts 50 Hz...

Страница 16: ...Inspections performed as part of the scheduled maintenance work can be performed on the installed system at site of installation All other repairs must be performed at a suitable place of work Only t...

Страница 17: ...e wheels of the bed are working correctly The moving and braking functions must be working correctly For electrically adjustable beds perform a visual and functional check of the drives These are subj...

Страница 18: ...136 170 01 Version 05 2018 18 Maintenance safety check in accordance with 6 of the German Medical Device Operator Ordinance MPBetreibV This form is available to download from our website www freistil...

Отзывы: