ELECTRICAL CONNECTION
•
The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking
device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example: circuit breakers,
fuses or contactors.
•
If the appliance is not fi tted with an accessible plug, disconnecting means must be incorporated in the
fi xed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or even.
Caution !
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a medium screwdriver.
Place it in the slits and open the cover.
ELECTRICAL CONNECTION
* calculated with the simultaneous factor following the standard EN 60 335-2-6
•
SETTING UP THE CONFIGURATIONS:
Attention!
For the various kinds of connection, use the brass bridges which are in the box next the terminal
• MONOPHASE
230V~1P+N
Put a bridge between terminal L1 and L2.
Put a bridge between terminal N1 and N2.
Attach the earth to the terminate “earth”.
Attach the neutral N to one of the terminals N1 or N2.
Attach the Phase L to one of the terminals L1 or L2.
• BIPHASE
400V~2P+N
Put a bridge between terminal N1 and N2.
Attach the earth to the terminate “earth”,
Attach the neutral N to one of the terminals N1 or N2,
Attach the Phase L1 to the terminals L1
Attach the Phase L2 to the terminal L2.
Caution!
Ensure that you correctly attach the wires and tighten the screws properly.
We cannot be held responsible for any incident resulting from incorrect connection or which could arise from
the use of an appliance which has not been earthed or has been equipped with a faulty earth connection
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2.5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *