background image

Page 6 of 12 

Rev A - 10/2022

If there is only one carer 
available, a mobile or 
overhead hoist can be used to 
facilitate this stage.  
Please ensure the operator of 
the hoist is trained to do so. 

Using the loops on the under 
surface of the quilted top 
sheet as shown in the image 
opposite, the client can be 
moved up and down the bed 

or to either side of the bed surface utilising the hoist method. 

As shown below, the system can also be used for manually turning a person. 

Please see the steps shown 
in images a thru c 

999037 

Bed management system User Manual 

Содержание 999037

Страница 1: ...Bed management system User Manual 999037 Bed management system User Manual...

Страница 2: ...ement system components 4 5 Operating Usage Instruction 5 to 6 6 Hoist usage 7 7 Cleaning 8 7 1 Laundering 8 7 2 Drying 8 8 Standards applied 9 9 User notes 10 to 11 10 Contact details 12 Symbols in u...

Страница 3: ...to using this device Store this manual with the documents included with the device and sling s Contents of this manual are subject to change without prior written notice 2 Contraindications There are...

Страница 4: ...suitable lifting device the combination of use will enable a safe working environment for both patient and carer 4 Bed management system components Please familiarise yourself with the components of...

Страница 5: ...ent This will provide extra safety for people with certain conditions The quilted sheet can be used without a normal bed sheet however it is advisable to place a normal cotton sheet over it It is advi...

Страница 6: ...d to do so Using the loops on the under surface of the quilted top sheet as shown in the image opposite the client can be moved up and down the bed or to either side of the bed surface utilising the h...

Страница 7: ...dy support wedge this piece of equipment enables to client to be supported without a carer having to adopt a static posture for lengthy periods Once the person has been repositioned the curtain must b...

Страница 8: ...ng the system should be laundered with soap or detergent at 50 C on a standard domestic cycle Disinfection the system should be laundered to ensure a period at temperature of 10 minutes at 65 C 3 minu...

Страница 9: ...t have been applied to the device are as follows BS EN ISO 10535 Hoists for the transfer of disabled persons Requirements and test methods BS EN ISO 12182 Assistive products for persons with disabilit...

Страница 10: ...Page 10 of 12 Part No 999037 Rev 2 Mar 2018 User notes 999037 Bed management system User Manual...

Страница 11: ...Page 11 of 12 Part No 999037 Rev 2 Mar 2018 User notes 999037 Bed management system User Manual...

Страница 12: ...7 Rev 2 Mar 2018 ________________________________________________________________ Prism Medical UK Unit 1 Tir LLwyd Industrial Estate Kinmel Bay UK LL18 5JZ email info prismmedical co uk 999037 Bed ma...