Installation
38
Installation Option 1 for Freedom 10, 15, 20, 25 D/D, 30,
and 30 D/D
Inverter Mode
Single Input/Single Output
External Power
Source
Single 30-amp shore power source, supplied through a 30-amp
branch rated main breaker
Power for AC loads
Power is supplied through the inverter in charge/transfer
mode, or by the inverter in invert mode.
Charger
Shares power with the AC loads. It can transfer up to 30-amps.
Installation Notes
1. When installing a Freedom 25 D/D or 30 D/D model, the
AC Input 2
and AC Output 2 wires are not used. They
must be capped off.
2. If a generator is installed in the system, use a break-before-
make AC transfer switch to switch between shore power
and generator power. Route AC output from the transfer
switch to the input of the inverter/charger.
Connecting Appliances
To prevent overloading the inverter or rapidly discharging the
battery bank, you should not connect any heavy load appli-
ances to the Inverter AC Panel. Heavy load appliances include
space heaters, stoves, water heaters, air conditioners, AC to
DC converters, or other battery chargers. If these types of
loads are present, they should be turned off when you are
using inverter power.
If you do not want to manually manage your energy usage,
consider using a different installation option.