![Freedom 458 Series COMBI Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/freedom/458-series-combi/458-series-combi_owners-manual_2329797027.webp)
23
Installation
4. Connect the other end of the wire to the ground bus in
your AC electrical system.
5. Make sure the connection is clean and tight.
Step 3: Install ground fault circuit interrupters
Certain branch circuits must be equipped with a Ground Fault
Circuit Interrupter (GFCI) to conform to NEC regulations.
Please consult the code or a qualified electrician for details.
Underwriters’ Laboratories has tested the following GFCI, and
we recommend using it.
•
Receptacle Type:
Pass & Seymour
Catalog Number:
1591
Rated:
15-amps at 120-volts AC
Warning
Use only the GFCI type receptacles detailed in this manual. These
will provide you protection against the risk of electric shock. Other
types may not operate properly when connected to this inverter,
resulting in a potential shock hazard.
To install the GFCI type receptacles
•
Refer to GFCI manufacture’s recommendations and to the
NEC requirements for proper installation.
Step 4: Connect the battery cables
Caution
Do not connect the Freedom Inverter/Charger to the engine starter
battery.
Warning
The Freedom Inverter/Charger is not DC reverse polarity protected.
Be very careful to connect the negative and positive cables to the
proper terminals. If the cables are reversed, you will damage your
unit and void your warranty.