8

®

Automatic data logging

The Watt & Energy Meter 4075.50 can be connected 
to a serial port on a computer. This can be used for 
controlling and reading the instrument from the PC 
and to read the built-in data logger.

If you want to communicate directly with the device 
– e.g. via a terminal program like HyperTerminal - see 
”Command Summary” later in the guide.

For interactive data acquisition on the PC, the pro-
gram  Datalyse  (download  from  datalyse.dk)  is  re-
commended.

The instrument can collect data without connection 
to a computer, as it is equipped with a memory of 
255 data record. Data is collected once every 10 se-
conds. When memory is full, data will automatically 
be compressed to take up half the memory by storing 
the mean of 2 consecutive records. For subsequent 
measurements, the interval between measurements 
is doubled, after which the process is repeated, etc.

From a computer, the data logging may instead be 
set to stop after a certain time.

Read-back of the acquired data can only be done via 
a computer with a terminal program.

Start and stop of data logging takes place with the 
buttons on the front, while the rest of the communi-
cation  always  takes  place  through  the  serial  inter-
face.

Managing the data logger starts with simultaneously 
pressing the two buttons 

Function

 (3) and 

Reset

 (4). 

The  display  shows 

Log,

  immediately  followed  by 

one of three status messages:

Rdy

 

the instrument is ready for data logging

On

  

data logging started

Off

  

data logging stopped

You  can  switch  between  the  above  situations  by 
pressing (3) and (4), as outlined below:

Initial state  Press 

Function

 (3) 

Press 

Reset

 (4)

Rdy 

➞ 

On 

➞ 

Off

On 

➞ 

Off

 

No change

Off

 

Free memory: 

 

On 

➞ 

Rdy

 

memory full: 

 

No change

Data logging starts as soon as status is 

On

. To stop 

data logging, switch status to 

Off 

(press 

Reset 

and 

Function

 simultaneously, and then 

Function

). When 

switching from 

Rdy

 to 

On

, all memory is reset.

Содержание 4075.55

Страница 1: ...sand RMS v rdi Ieff VA Tilsyneladende effekt Ueff Ieff Faseforskydning mellem sp nding og str m W Afsat effekt sand RMS v rdi P Ueff Ieff cos Ws Afsat energi siden sidste tryk p Reset P t Wh Afsat en...

Страница 2: ...eset 1 2 4 3 5 6 7 Load DK 6870 Denmark CAUTION To avoid electrical shock the power cord protective grounding connector must be connected to ground ADVARSEL D ksel m ikke fjernes p grund af fare for e...

Страница 3: ...ilsluttet forsyningssp nding og belastning til denne uanset om der er tilsluttet forsyningssp nding og belastning p forpladen Der registreres to separate tider for energiomr derne Ws og Wh Funktionen...

Страница 4: ...ter displayet viser Log og umiddelbart efter en af f lgende tre statusmeddelelser Rdy instrumentet er klart til dataopsamling On instrumentet opsamler data Off instrumentet opsamler ikke data Der kan...

Страница 5: ...S v rdi P Ueff leff cos Ws Energy consumption since last Reset P t Wh Energy consumption since last Reset P t Hz Frequency for AC Time Elapsed time since last Reset Please note that the two energy ran...

Страница 6: ...7 Load DK 6870 Denmark CAUTION To avoid electrical shock the power cord protective grounding connector must be connected to ground ADVARSEL D ksel m ikke fjernes p grund af fare for elektrisk st d Ov...

Страница 7: ...nnected to supply voltage and load irrespective of any con nections on the front panel Two separate times are registered for the two energy ranges Ws and Wh The function is indicated by Ws and time si...

Страница 8: ...hich the process is repeated etc From a computer the data logging may instead be set to stop after a certain time Read back of the acquired data can only be done via a computer with a terminal program...

Страница 9: ...ill vary depending on the number of data transmitted in some cases it may take several seconds The format is Time for transmission of data Status of the instrument Collected data year month date hour...

Страница 10: ...el 2 13 Start time Format ssmmhhddmmyy ss sec mm minute hh hour dd day mm month yy year 14 19 Power level Format xxxx xx in Watt 20 Log layout 1 automatic compression 2 fixed time 21 28 Logging time F...

Страница 11: ...me status EMT ESMT T Read internal clock V Returns the version number e g Watt Energy meter English version 3 0 W Set the internal clock On request type new data Returns the help menu listing the foll...

Страница 12: ...12 ctrl A A Automatic summer time DST on ctrl 0 0 Automatic summer time DST off Accessories and spare parts RS232 serial cable 1123 20 25 25 pin 1123 05 25 9 pin Fuse 4090 42 100 mA T...

Отзывы: