TH4C Installation Guide
p. 32
TH4C Basic Configuration
© Safe Fleet | May 2019 | All rights reserved
Document Number: XE-SNB2-TH4CPM-R0A
ITEM
DESCRIPTION
VALUE [DEFAULT]
Alarm
Click to display settings for the selected Alarm
.
By default, Alarm1 is connected to the DVR Event/Diagnostic button.
Alarms 2-4 can come from Signals, GPS geo-fencing, G-sensor, or
Excessive Speed.
[Alarm1], Alarm2,
Alarm3, Alarm4
Duration
The length of time after the alarm has been triggered that flagged
video is recorded at the alarm speed (FPS), quality, and resolution
settings described below
.
0, 5, 10, [30] sec., 1,
3, 5, 10, 15, 20, 30, 45
min
Input
Applies to Alarm 1 only
. When triggered with the Seon Event/Diagnostic
button, use the default setting.
Control how the alarm input senses activation
: choose "N.O." (Normally
Open) if the circuit rests at 0 VDC and goes to 12 VDC when active; choose
N.C. (Normally Closed) if the circuit rests at 12 VDC and drops to 0 when active.
[N.O.], N.C.
FPS
For each channel, the recording speed in FPS
(Frames Per Second)
used when the alarm is triggered
.
If the DVR normally records at a mid-range or low FPS to conserve storage
space, set a higher FPS value to increase video quality for a short duration
to record an alarm event.
OFF, 1, 5, 7, 10, 15, 20,
[30] FPS
Quality
For each channel, the recording quality used when the alarm is triggered
.
The DVR offers a range of quality settings, from 1 (low) to 4 (high).
1, 2, [3], 4
Resolution
For each channel, the recording resolution (in pixels) used when the
alarm is triggered.
The higher the recording resolution, the better the
picture looks, but the shorter the recording time on a hard drive.
Details depend on the camera connected to the channel (HD 720p or
Standard Definition). The highest supported resolution is the default, and
two lower-quality options are available.
[1280 x 720].
[720 x 480].