Table 2. Error Codes
Table 3. Fault Warning Codes
RPM
Message
Display
Display
Probable Cause
E01
NO DATA
>Datalink cable not connected / connected to wrong port
>Broken wire / bad connector contact on datalink cable
E02
NO RESP
No responce to control signal
E03
NO RPM
>Datalink cable not connected / connected to wrong port
>Engine not running / ignition key on
>Broken wire / bad connector contact on alternator cable
E04
N/A
N/A
E05
NO PSR
Pressure sensor not detected
E06
N/A
N/A
E07
N/A
N/A
E08
TRANS T’
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective temperature sensor
E09
ENG OIL’
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective pressure sensor
E10
ENG T’
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective temperature sensor
RPM
Message
Display
Display
Description
F01
N/A
F02
N/A
F03
HI RPM
High RPM
F04
Pump Hot Pump overheat
F05
Pump cavitation
F06
Tran Temp High transmission temperature
F07
Low Batt
Low battery voltage
F08
Hi Batt
High battery voltage
F09
Low Oil
Low engine oil pressure
F10
Eng Temp High engine coolant temperature