DF4000 Rev0204
29
Remote
Display Cable
Figure 9. Remote Display Wiring
Primary Display
Connector
Note:
The remote display connector
pinouts are the same as the primary
display connector pinouts.
Note:
The pin lock and two pin plugs have to
be removed to insert the pins from the remote
display harness. Reinstall the pin lock after
the two pins from the remote are inserted.
Note:
To connect multiple displays on
the datalink:
Connect pin 7 of each display together.
Connect pin 8 of each display together.
Black Wire
Ground
Red Wire
9 - 30 VDC
To Primary Display
Connector
Black Wire to Pin 7
Red Wire to Pin 8
Pin Lock
Pin Plugs
Note
: Minimum
wire size for power
is 18 AWG.