The screen will then read 

“DESIRED BUTTON”

• 

press and release the button 

you wish to operate the doors 

with

2. 

The screen will display “HIDDEN 

BUTTON” again

• 

You can repeat the remote 

leaning process, or press [OK] 

to end

Programming after the completed Autoset

If the doors are in the closed position after the 

Autoset is complete you can move on to Step 

2. If they end in the open position, then you 

need to adjust your programming and follow 

the instruction for step 1.

1. 

 To get into the programming menu 

press [OK] twice quickly

• 

“HALT” will appear on the 

display

• 

Press [OK] twice again 

• 

“PARAM” will appear on the 

display

• 

Use [–] button to scroll to 

“LOGIC” 

• 

Press [OK]

• 

Use [–] button until you see 

“OPEN IN OTHER DIRECT” 

• 

Press [OK]

• 

 Adjust the value to 1

• 

Press [OK]

• 

Press [+] and [–] at same time 

twice to exit menu

• 

Test doors again

Continuous Force Learning Mode

2. 

Go into “LOGIC” menu again press [OK] 

(if you did not complete Step 1 then 

press [OK] twice quickly, “HALT” will 

display and press [OK] twice again)

• 

Scroll till you see “ICE” and 

press [OK]. Change value to 1 

and press [OK]. This continues 

force learning mode on every 

cycle. 

• 

Scroll down with [–] button 

until you see “SAFE 1” (this is in 

“LOGIC” too) 

• 

Press [OK]

• 

Change value to 5 to ignore 

photo sensors on open 

• 

Press [OK]

Programming for Wired Wall Button

3. 

Scroll down with [–] button until you 

see “IC 1” 

• 

Press [OK]

• 

Adjust the value to 000 

• 

Press [OK]

• 

Press [+] and [–] at the same 

time to exit the menu

Troubleshooting

Doors close instead of open when photo eyes 

are interrupted

• 

If you are having trouble with the doors 

reversing the incorrect direction when 

the photo beam is interrupted, then you 

can do one of these two things:

1. 

 Go to the logic menu and change 

the direction 

              2. Swap the motor power wires (#10 & 

#11 and #14 & #15)

Motors are trying to open the wrong direction

• 

If the motors are trying to pull in instead 

of out, then the polarity is incorrect; and 

you want to double check your wiring 

and make sure it matches the wiring 

simplified diagram.

Wrong door is opening first 

• 

If the wrong door is opening first then 

you have the wrong motor wired into 

10, 11, and 42, and will need to switch 

Содержание Thalia

Страница 1: ...Addendum for Franklin Manual Thalia Model Updates for 2019 ...

Страница 2: ...Brilliantly engineered this state of the art automatic swing garage door opener offers quiet operation and delivers superior torque ...

Страница 3: ... 2 Programming the Wired Wall Button from Start of Menu 3 Homelink Programming 3 Wireless Wall Button Programming 4 Outdoor Keypad Programming 4 Programming the Keypad 5 Changing the Default Code for Channels 5 Additional Codes 5 Changing a Current Passcode 5 Regular Use of Outdoor Keypad 6 Outdoor Keypad Reset 6 Wi Fi Hub 6 Error01 Troubleshooting 7 Manufacturer s Step by Step Guide for Error01 7...

Страница 4: ......

Страница 5: ... typical garage door Press OK Note AR will cause the doors to automatically close on their own SR requires you to press a button to close 6 After selecting your preset the screen will display PROG programming for a few seconds The screen will then display AUTOSET Be sure the path of the doors is clear of traffic and obstructions Be aware that the doors will run at full torque during the process Pr...

Страница 6: ...ce quickly HALT will display and press OK twice again Scroll till you see ICE and press OK Change value to 1 and press OK This continues force learning mode on every cycle Scroll down with button until you see SAFE 1 this is in LOGIC too Press OK Change value to 5 to ignore photo sensors on open Press OK Programming for Wired Wall Button 3 Scroll down with button until you see IC 1 Press OK Adjust...

Страница 7: ...at the input command to be reprogrammed on the control board to open and close the doors If you do not program the control board the wall button will only open the doors To change the default setting of OPEN to a START input please follow these steps On the control board please press OK twice quickly HALT will appear on the display press OK twice again and PARAM will appear on the display Press th...

Страница 8: ... display Press the button one time and the display show LOGIC Press the OK button TCA will appear on the display Press the button until you see IC 1 and press OK Adjust the IC 1 to value of 000 Wireless Wall Button Programming Note Please see manufacturer instructions for assembly 1 Press OK button four times to get into the menu system Scroll with minus button down to rAdio Press OK 2 The display...

Страница 9: ... on the keypad Green LED will blink twice Wait 5 seconds Changing the Default Code for Channels 5 To change the default code press and hold ON button on the keypad Make sure red LED light is on Press 1 1 1 1 Press OK Red LED light will be fixed and green LED will blink 6 Enter the desired 4 digit code sequence Press OK Red LED light will be fixed and green LED will blink 7 Repeat step 6 to confirm...

Страница 10: ...he openers with an app on your smart phone Before you proceed you must have the following Wi Fi Hub accessory Thalia model Franklin it will say Thalia in the control box or it has grey control unit housing instead of black Have strong Wi Fi connection where the control unit is located Own a smart phone Installation Steps 1 With the control board OFF insert the Wi Fi Hub to the appropriate location...

Страница 11: ...ror01 Troubleshooting If you experience an issue during the Autoset and KO displays on the screen press OK An error code will then display If it is Error01 then that indicates an issue with alignment or wiring for the photo eyes Please follow the below troubleshooting guide to try and resolve the issue Be sure the wiring matches the diagram in Wiring Simplified or table below Check all three fuse ...

Страница 12: ...ms 8 If photobeam continuity checks out then remove the cables 70 72 from the board and put your meter to them and set it to ohms Now put your hand in and out of the way and see if the continuity is changing between short and open Note If not check you wiring 9 If all this works then move the receiver s power lead back between 50 52 Note 50 52 ONLY have power when the motors are moving 10 Put your...

Страница 13: ...Please visit our website and download our most up to date manual Please call us directly at 1 800 694 5977 for additional assistance ...