background image

MAINTENANCE

Draining the Pump

6

MAINTENANCE

NOTE:

 For replacement parts, consult the catalog available on 

www.FranklinWater.com.

• Check the pump periodically for loose or rubbing parts. 
• Service immediately if any unusual noise, leaks, or vibrations develop. 
• Drain the pump should it be subjected to freezing temperatures.

Draining the Pump

Drain all piping and water tanks exposed to freezing conditions.
1. Remove the pipe plug from bottom of pump case.
2. Allow the water to drain.
3. Install the pipe plug to the pump case.

Disassembly

1. Shut down system and lock out power.
2. Allow pump components to adequately cool.
3. Drain the pump. Refer to 

“Draining the Pump” on page 6

.

Pump Shaft Disassembly

1. Unbolt and remove the casing, laying aside the case gasket.
2. Take the diffuser and square ring off the volute.
3. Remove impeller and shaft key:

IMPORTANT:

 Beware of breaking the back side of the impeller.

• Remove the impeller bolt and washer.
• Pry the impeller from the shaft. For corroded assemblies, flip the pump vertically and apply a 

penetrating oil to the impeller.

• Remove the shaft key.

4. Spray the shaft sleeve with WD-40 and remove the rotating portion of the mechanical seal.
5. Unbolt the motor adapter from the motor and remove.

IMPORTANT:

 Be sure not to damage the stationary part of the mechanical seal.

6. Gently tap the stationary part of the mechanical seal from the motor adapter using a flat-blade 

screwdriver and rubber mallet.

7. If necessary, remove the shaft sleeve and slinger.

• Clean the shaft sleeve with 000 steel wool and WD-40.

8. Inspect disassembled components. Replace the worn parts with new during reassembly. 

Risk of severe injury or death by electrical shock.

• To reduce risk of electrical shock, disconnect power before working on or around the system. 

Содержание Turf Boss FTB3CI

Страница 1: ...andUL This product is covered by a limited warranty for a period of 1 year from the date of original purchase by the consumer For complete warranty information refer to www FranklinWater com Specifica...

Страница 2: ...circuit equipped with a ground fault circuit interrupter GFCI device if required by code The pump includes a grounding connector To reduce risk of electric shock be certain that it is properly connec...

Страница 3: ...vide adequate room for future servicing protection from freezing temperatures flooding and equipment drainage Bolt unit down evenly on a good foundation preferably concrete to prevent unnecessary stre...

Страница 4: ...valve All discharge piping must have a pressure rating capable of withstanding the incoming inlet pressure plus the pump s maximum shut off head pressure IMPORTANT Do not operate the pump under a no...

Страница 5: ...f three wires either at the motor or starter 3 Start the pump 4 Gradually open the discharge valve to the halfway point If the pump does not deliver water within seconds stop the motor and prime pump...

Страница 6: ...ring off the volute 3 Remove impeller and shaft key IMPORTANT Beware of breaking the back side of the impeller Remove the impeller bolt and washer Pry the impeller from the shaft For corroded assembl...

Страница 7: ...otate the sleeve at least two times before fully seating the sleeve against shaft shoulder Wipe off excess lubricant Let stand 3 minutes 3 Insert a new stationary portion of the mechanical seal into t...

Страница 8: ...impeller System head too high Reduce system head back pressure on pump or resize pump Excessive suction lift or losses or NPSHA too low for the pump Locate pump closer to the water source increase pip...

Отзывы: