9. Place the square ring and diffuser on the volute.
10. Reposition the case gasket and bolt the volute to the motor adapter.

• Use Blue Loctite 243 on bolts.
• Torque to 20 ft-lbs.

Troubleshooting

Problem

Probable Causes

Corrective Action

Motor Fails to Start or 

Not Running

Motor thermal protector tripped

Correct cause for high amperage, such as low voltage or excessive 

pumping.

Open circuit breaker or blown fuse

Check electric wiring and motor for short circuits and correct.

Impeller binding

Remove pump case and check for debris.

Motor improperly wired

Check complete suction line and all fittings for air leaks and verify 

foot valve has adequate submergence.

Defective motor

Take to an authorized motor shop for repair or replacement.

Little or no discharge

Pump is not primed: air or gases in 

pumpage

Check suction line and foot valve for leaks. Make sure that water 

level has not dropped to uncover suction inlet. Prime pump.

Discharge or suction plugged or valve 

closed

Clear obstructions from suction and discharge lines.

Incorrect rotation (3-Phase only)

Interchange any two of three wires either at the motor or starter.

Low voltage or phase loss

Correct incoming power to match motor nameplate requirements.

Impeller worn or plugged

Clean or replace impeller.

System head too high

Reduce system head (back-pressure on pump) or resize pump.

Excessive suction lift or losses, or NPSHA 

too low for the pump

Locate pump closer to the water source, increase pipe size or resize 

pump.

Low pump capacity or 

pressure

Valves in suction or discharge lines par

-

tially closed

Open valves to reduce possible restrictions.

Suction or discharge line partially 

plugged

Clear obstructions from discharge line.

Wrong pump rotation

Correct to proper rotation.

Excessive power 

consumption

Impeller binding

Remove pump case and check for debris.

Discharge head too low creating exces

-

sive flow rate

Close down discharge valve to increase pressure and throttle back 

flow rate.

Fluid viscosity: specific gravity too high Modify fluid properties or resize pump.

Excessive noise and 

vibration

Impeller binding

Remove pump case and check for debris.

Pump is not primed: air or gases in 

pumpage

Check complete suction line and all fittings for air leaks and verify 

foot valve has adequate submergence.

Discharge or suction plugged or valve 

closed

Clear obstructions from suction and discharge lines.

Impeller worn or plugged

Clean or replace impeller.

Excessive suction lift or losses. NPSHA 

too low for the pump

Locate pump closer to the water source, increase pipe size or resize 

pump.

Discharge head too low, creating exces

-

sive flow rate

Close down discharge valve to increase pressure and throttle back 

flow rate.

Worn bearing

Check bearing for damage and replace if necessary.

Pump, motor, or piping loose

Verify all connections and mountings are secure and piping sup

-

ported.

Water leakage at pump 

shaft

Defective seal assembly

Replace seal.

Содержание Turf Boss FTB3CI

Страница 1: ...andUL This product is covered by a limited warranty for a period of 1 year from the date of original purchase by the consumer For complete warranty information refer to www FranklinWater com Specifica...

Страница 2: ...circuit equipped with a ground fault circuit interrupter GFCI device if required by code The pump includes a grounding connector To reduce risk of electric shock be certain that it is properly connec...

Страница 3: ...vide adequate room for future servicing protection from freezing temperatures flooding and equipment drainage Bolt unit down evenly on a good foundation preferably concrete to prevent unnecessary stre...

Страница 4: ...valve All discharge piping must have a pressure rating capable of withstanding the incoming inlet pressure plus the pump s maximum shut off head pressure IMPORTANT Do not operate the pump under a no...

Страница 5: ...f three wires either at the motor or starter 3 Start the pump 4 Gradually open the discharge valve to the halfway point If the pump does not deliver water within seconds stop the motor and prime pump...

Страница 6: ...ring off the volute 3 Remove impeller and shaft key IMPORTANT Beware of breaking the back side of the impeller Remove the impeller bolt and washer Pry the impeller from the shaft For corroded assembl...

Страница 7: ...otate the sleeve at least two times before fully seating the sleeve against shaft shoulder Wipe off excess lubricant Let stand 3 minutes 3 Insert a new stationary portion of the mechanical seal into t...

Страница 8: ...impeller System head too high Reduce system head back pressure on pump or resize pump Excessive suction lift or losses or NPSHA too low for the pump Locate pump closer to the water source increase pip...

Отзывы: