2
TABLE 1
CAUTION
Undersize wire between the motor and the power source will adversely
limit the starting and load carrying abilities of the motor. Minimum wire
sizes for the motor branch circuits are recommended in table 1.
TABLE 2– FRICTION LOSS CHART FOR PLASTIC PIPE:
For galvanized pipe, double the fi gures.
Loss of head in feet, due to friction per 100 feet of pipe.
Loss of head in meters, due to friction per 100 meters of pipe.
1-1/4" Suction
Hose
Foot Valve
Priming Plug
Street Tee (not
included)
Garden Hose Adaptor
(included)
To Sprinkler System
Garden Hose
Weather Proof Enclosure
To 115v
Grounded Outlet
Base
To Sprinkler
System
Handle
To 115v
Grounded
Outlet
Base
INSTALLATION
ALTERNATE INSTALLATION AS A BOOSTER PUMP
Garden Hose
Street Tee
(not included)
1-1/4"
Suction Hose
Garden Hose Adaptor (included)
Fig. 1
Nominal
Pipe Size
U.S.
GPM
3/4"
1"
1"-1/4''
1-1/2''
2''
4
3.75
1.15
0.30
0.14
–
5
5.66
1.75
0.46
0.22
–
6
7.95
2.45
0.65
0.31
–
7
10.60
3.25
0.86
0.41
–
8
13.50
4.16
1.10
0.52
–
9
16.80
5.17
1.35
0.65
–
10
20.40
6.31
1.67
0.79
0.23
11
24.40
7.58
1.98
0.95
0.27
12
28.60
8.85
2.33
1.10
0.32
14
38.00
11.80
3.10
1.46
0.43
16
48.60
15.10
3.96
1.87
0.55
18
60.50
18.70
4.93
2.33
0.69
20
73.50
22.80
6.00
2.83
0.84
Nominal
Pipe Size
L/Min.
20mm
25mm
32mm
40mm
50mm
15
3.7
1.15
0.30
0.13
–
20
5.3
1.64
0.43
0.19
–
25
7.1
2.18
0.56
0.27
–
30
13.5
4.13
1.08
0.49
–
35
16.3
5.00
1.31
0.61
–
40
23.5
7.30
1.90
0.88
0.25
45
28.3
8.74
2.31
1.07
0.29
50
34.2
10.60
2.79
1.32
0.38
55
40.7
12.60
3.32
1.56
0.46
60
48.1
14.90
3.92
1.85
0.54
65
55.7
17.30
4.45
2.15
0.63
70
63.8
19.70
5.20
2.46
0.73
75
72.2
22.40
5.89
2.78
0.83
Reccommended Wire Gauge For Electrical Cord Length
HP
Volts
0-25 ft.
50ft.
100ft.
150ft.
200ft.
1/2
115
14
12
10
8
6