- 9 -
ZMI
_001_
2030
0485
72-P
W
C3O00
02_#
SEN_#
AQU_#
V
2.
fm
10.16
Connect the cables between the electronics module, power switch, and sensor.
A: Power switch (actuator 1)
B: Actuator 2 (optional)
C: 0-10 V analogue output
D: Cold water temperature sensor (optional)
E: Hot-water temperature sensor (optional)
F: Capacitive sensor (sensor connection 2/3)
G: Not used (sensor connection 1)
H: Electrical T distributor system cable (power)
K: Electronic module
10.17
Connect the cables between the electronics module, solenoid valve, and hand dryer.
F: Electronics module (actuator 1)
G: Solenoid valve
H: Switch contact for hand dryer
11. Assembly of hand dryer
11.1
Attach the mounting template to the wall. The recommended mounting height is
between 130 and 140 cm above the floor.
11.2
Drill the mounting template accordingly (A, B, C, D).
11.3
Remove the mounting template from the wall. Insert the wall plugs.
11.4
Turn out the two screws (a) on the housing.
11.5
Remove the hand dryer housing.
11.6
Guide the electrical cable and the cable of the power switch through the base plate.
11.7
Mount the base plate and motor to the wall.
1 Screw
2 Washer
3 Spacer
4 Base plate
5 Washer
6 Nut
11.8
Connect the electrical cable (a).
L: Red (or brown)
N: Black (or blue)
: Green (or yellow)
11.9
Connect the cable of the power switch (b).
11.10
Screw the housing (c) to the base plate.
11.11
Shorten the hose (d).