- 7 -
ZMI
_001_
2030
0485
72-P
W
C3O00
02_#
SEN_#
AQU_#
V
2.
fm
10. Assembly
Warning!
• Place the power supply (not part of the delivery, see
, accessories)
outside the wet area in a separate room.
• Operate the product only with safety extra low voltage (SELV). The components
must not be earthed.
• Protect the power supply with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
Lay the system line (not part of the delivery, see
, accessories) in an
empty pipe (to be provided by the customer) from the power supply to the taps and
loop through.
Warning!
Only operate taps with the designated filter.
Failure to observe this instruction can result in damage to the tap.
10.1 Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
10.2
Establish the water connection.
☞
Take note of the flow direction.
10.3
Use an Allen key to close the water volume regulator.
a: Closed
b: Open
10.4
Unscrew the locking screw (c) on the water volume regulator.
10.5
Replace the (d) filter.
☞
Important!
Note the installation position of the filter.
10.6
Remove the flush connector.
10.7
Attach the connection cable.
10.8
Insert the solenoid valve with the seals.
☞
Take note of the flow direction.
10.9
Open the water volume regulator (see
).
10.10
Affix the sensor (e) to the rear of the plastic tile (f).
☞
No tile cement may be applied between the sensor and the plastic tile.