L:\INFORM\CDFrifri\2006\frifri\English\Technic\Manuals\215122
31/01/2006 Page : 47/51
Elegance «M »
Error 1 :
Break down or disconnection of the working probe
Error 2 :
Overheating, the temperature of the frying oil is over
225°C
Error 3 :
Connection of the working probe is inverted
7.2 Safety Thermostat
The deep fryer is equipped with a safety thermostat according to the current regulations.
The safety thermostat triggers at a temperature of 225 °C.
The safety thermostat switches off the deep fryer in the following situations:
CAUTION
. The control thermostat is defective.
. If the connecting of the temperatures probes is defective.
. A power failure (mains) has occurred.
. The frying oil temperature is too high.
. The heating elements are heating « dry » i.e. no frying liquid is present.
. Too little frying liquid is present.
To restart the fryer after a shut down by the safety thermostat, a pass through the position « 0 » is required.
ADVICE
. Clarify reason for the triggering of the safety thermostat.
8. Shutting down and storage
This section provides the necessary advice for the situation where the owner/operator of the deep fryer
wishes to shut the appliance down and store it for a long period.
This refers to the desired shutdown of the deep fryer and not the non-use of the appliance for operating
or production reasons.