30
Safety functions and error display
ERROR CODE
ERROR DESCRIPTION
INSTRUCTION MANUAL
E03 + continuous
tone, or
Continuous key activation, control switches off
after 10s. Liquid or cookware on glass above
control.
Clean glass ceramics. If the problem persist,
contact authorized center for technical
assistance - specifying the error code
U400
Wrong connection. Input voltage >300V.
Inspection mains connection. If the problem
persist, c
ontact authorized center for technical
assistance - specifying the error code
ER20
Flash error. Flash Rom check sum wrong.
Programming options wrong. Component part
error Touch control. Transmission of wrong
configuration data.
Contact authorized center for technical
assistance - specifying the error code
Er22
Key evaluation defect, Touch control switches
off after 3.5-7.5s. Short circuit or interruption
near
the key evaluation.
Contact authorized center for technical assistance
- specifying the error code
Er31
Configuration data wrong.
TC assignment to induction series wrong.
No or partial functions.
Automatic configuration of filter boards caused
by wrong TC type.
Component part error on TC or filter board
Contact authorized center for technical
assistance - specifying the error code
Er47
Communication error between TC und
induction.
TC defect. TC cable not correctly plugged on
or defect.
Power unit defect.
Contact authorized center for technical
assistance - specifying the error code
Er36
Short circuit at the temperature sensor of the
TC.
Contact authorized center for technical
assistance - specifying the error code.
Er37
Return of sliding register signals to select,
segment or relay triggering incorrect.
Contact authorized center for technical
assistance - specifying the error code.
Er42
5V at the controller outside the valid range or
too much variance.
Contact authorized center for technical
assistance - specifying the error code.
EA
Cooling body temperature sensor not plausible
One control pulse recognized on switched-off
cooktop. AD converter defect.
Component part error on power unit.
Contact authorized center for technical
assistance - specifying the error code.
E2
Over-temperature cooktop.
Cooktop overheated (cooking with empty pan)
Return heat on coil sensors > switch-off
threshold.
Contact authorized center for technical
assistance - specifying the error code.
E4
Configuration not plausible.
Contact authorized center for technical
assistance - specifying the error code.
E5
Mains voltage signal invalid.
Power unit defect.
Picoflex or tube not correctly.
plugged on or cable defect.
Filter board defect.
Contact authorized center for technical
assistance - specifying the error code.
E6
Power unit defect.
Picoflex or tube not correctly.
plugged on or cable defect.
Filter board defect.
Contact authorized center for technical
assistance - specifying the error code.
E8
Fan defect.
Component part error.
Contact authorized center for technical
assistance - specifying the error code.
E9
Mechanic rupture of PT sensor.
Resistance value drifting off.
Power unit defect.
C
ontact authorized center for technical
assistance - specifying the error code.
E3
User Display: Pot inaplicable.
This error can have several modul-internal
reasons.
Contact authorized center for technical
assistance - specifying the error code.
E7
Sub LIN error between filter and power unit.
Contact authorized center for technical
assistance - specifying the error code.
Содержание FHI 754 4I ST CTX
Страница 47: ...LIB30446...