manualshive.com logo in svg
background image

27

 

selection of both cooking elements (the same as activation). 
If the bridge function is deactivated while in operation, than both cooking elements 
go to level “0” and can then be set again. 

 

Pause function 

The execution of the function is only possible if at least one zone is on. 
The pause condition may also be activated with cooking zone specific errors, 
here, the error display is hidden. Also residual heat indication, special 
messages such as A, P or no pan are hidden; the pause display has priority. 
If there is a general error during the pause, the control switches off and 
terminates the mode

 

Activating the Pause function 

 

Press the sensor (B), the led to the left of it lights on.  

 

All displays show the symbol “II” and all operations are locked. 

 

 

 

While the Pause function is active:

 

•  Any Timer (also Egg-timer) set before the pause will be stopped during the pause 

and continue when pause mode is quitted. 

•  A selected booster or heat up time automatic function is terminated. 
•  Residual heat calculation and maximum operation time limitations will not be 

interrupted and keep on working in the background. 

•  Functional LED’s such as Timer, multi-zone, ... keep on glowing according to their 

status. 

 

The pause mode can only be active for maximum 10 min. If the pause mode is 
not deactivated within 10min the control switches off automatically. 
Throughout the pause time the (A) button can be used to switch the control 
off. In this case the pause mode is also deactivated. 

 

Interruption of Pause function 

• Press (B). 
• Within 10 seconds press any key. 
The condition before the pause mode is restored. 

 

Recall function 
 

If the control was accidentally switched off through the main switch (A) all settings 
can be restored using the recall function. After switching the control off from the 
main switch the user has 6s to switch the control on again and then he has another 
6s to press the pause button (B) in order to recall the settings. The recall function 
can only be used if at least one cooking zone was active (cooking level >0) 
independent from key lock. 

 

Timer 

 

Use of timer facilitates cooking by setting the time of hotplate operation. 

 

Turning timer on 

•  The cooktop must be turned on and the zone where you want to set the timer 

must be working. 

•  Press the timer’s sensor ON/OFF (D), the symbol “00” blinks at the timer’s 

display.  

The timer symbol blinks near the display at all active zones. 
 

 

 
•  Press the cursor (E) of the cooking zone where you want to set timer, the timer’s 

led blinks near the display. 

•  The timer’s value is set by adjusting on the zone’s cursor. 
Sliding to the right the value increases, sliding to the left the value decreases in 
intervals of 1 minute. 
• When the finger is removed from the cursor, the timer starts to count the set time. 
The cooking level is shown at the indicator.  
The led near the timer’s display indicates that the timer is active. 

 

If the timer is set for more cooking zones, the zone with shorter remaining time will 
be indicated by the led to the right of the zone and by the led near the timer’s 

Содержание FHI 754 4I ST CTX

Страница 1: ...Manuale d istruzioni Piano di cottura da incasso 3 Operating and maintenance instruction for hobs Electric hobs 19 Manual de instrucciones Placa de cocci n empotrable 30 FHI 754 4I ST CTX...

Страница 2: ...2 Il produttore si impegna per continui miglioramenti Per questa ragione il testo e le illustrazioni in questo manuale possono essere cambiate senza preavviso...

Страница 3: ...tipi modelli d apparecchi per cui potreste trovare descrizioni di funzioni che il Vostro apparecchio non possiede Istruzioni di collegamento Il collegamento deve essere eseguito secondo il capitolo C...

Страница 4: ...e notate qualche difetto interrompete immediatamente l alimentazione elettrica In caso di disturbi staccare il cavo di alimentazione elettrica e chiamare il Servizio Assistenza L apparecchio non deve...

Страница 5: ...cottura a induzione a incasso A 750mm B 465mm C 740mm D 455mm E 45mm F 10mm G 50mm H 1 6mm Il piano cottura pu essere incassato solo nel piano lavoro di spessore fra 25 e 40mm L elemento inferiore de...

Страница 6: ...tivo omnipolare d interruzione Questo dispositivo deve assicurare una separazione dei contatti che fornisca una disconnessione completa nelle condizioni di sovratensione della categoria III Per la sic...

Страница 7: ...eramica ancora calda con i prodotti chimici perch quest ultima si pu danneggiare Pentole adatte per piano cottura ad induzione La zona cottura a induzione funziona perfettamente se usate le pentole ad...

Страница 8: ...eguimento cottura dopo riscaldamento forte 4 5 Cottura lenta grandi quantit 6 Cottura per arrostire rosolare il cibo 7 8 Cottura per arrostire il cibo 9 Inizio cottura arrosto A Riscaldamento veloce a...

Страница 9: ...alore Valore massimo Gestione piano cottura Al momento dell accensione del piano cottura in vetroceramica si accendono tutti gli indicatori per un attimo Il piano cottura pronto per l uso Il piano cot...

Страница 10: ...e il sensore F Il led sopra il tasto inizia a lampeggiare Entro 5 secondi premere sul cursore della zona cottura prescelta Nel display della zona cottura viene visualizzato il simbolo u Attivazione Ke...

Страница 11: ...ticolarmente potente zona cottura con simbolo P Per una cottura veloce potete usare sulle zone cottura indicate l impostazione per cottura particolarmente potente Cos con l aiuto di potenza aggiuntiva...

Страница 12: ...La condizione di pausa pu durare per max 10 minuti Se lo stato non terminato entro questo tempo il controllo si spegne La zona di cottura pu essere accesa o spenta in qualsiasi momento con il sensore...

Страница 13: ...impostato il Timer Premere il sensore D Premere una volta sola un punto qualsiasi del cursore E della zona di cottura di cui si vuole sapere il tempo residuo Sul display del timer verr visualizzato il...

Страница 14: ...adenza del tempo indicato nella tabella la funzione viene disinserita e la A si spegne Il sistema di cottura automatica pu essere disinserito in qualsiasi momento modificando il livello di potenza del...

Страница 15: ...Contattare il centro di assistenza tecnica autorizzato specificando il codice d errore Er42 L unit di controller oltre 5V fuori del range valido o troppa discrepanza Contattare il centro di assistenz...

Страница 16: ...i per eliminare il calcare Fig 3 La sporcizia pi ostinata si elimina con detersivi specifici per la pulizia delle superfici in vetroceramica Seguite i consigli del produttore del detersivo Attenzione...

Страница 17: ...17 The Manufacturer strives for continuous improvements For this reason the text and illustrations in this book are subject to change without notice...

Страница 18: ...re you may fi nd information and descriptions that may not apply to your particular appliance Installation instruction he appliance should be connected to the power supply in accordance with the instr...

Страница 19: ...case you notice any visible cracks on the surface cut the power supply immediately In case of any malfunctions disconnect the appliance from the power supply and call service department Do not use hig...

Страница 20: ...nd rear wall is indicated at the illustration for the installation of the built in cooktop Built in induction hob opening dimensions A 750mm B 465mm C 740mm D 455mm E 45mm F 10mm G 50mm H 1 6mm Induct...

Страница 21: ...on under overvoltage category III conditions Such appliances are allowed to be mounted on one side next to a high kitchen cabinet the height of which may exceed that of the appliance On the opposite s...

Страница 22: ...coil creates magnetic field at the bottom of the dish which can me magnetized which in turn originates whirling fl ows of current which then heat the hotplate IMPORTANT In case sugar or other heavily...

Страница 23: ...hat can be magnetized steel dishes enamel or steel alloy dishes induction hotplate will not function otherwise Power regulation Heating power of the hotplates may be set at nine different levels The f...

Страница 24: ...n all displays come on for a moment The hob is ready for operation The hob is fitted with electronic sensors which are switched on if you touch the relevant circle for at least one second Each sensor...

Страница 25: ...ted cooking zone The symbol u is shown at the cooking zone s display Activating Keep Warm 74 C Press the key G The led above it starts blinking Within 5 seconds press the cursor of the selected cookin...

Страница 26: ...inutes then automatically switches back on to the maximum normal level 9 During the time extra power is activated the power of other hotplates is limited This is indicated on the power display by inte...

Страница 27: ...l off In this case the pause mode is also deactivated Interruption of Pause function Press B Within 10 seconds press any key The condition before the pause mode is restored Recall function If the cont...

Страница 28: ...ssing any sensor or it turns off automatically after 2 minutes If you want to switch off the timer prior the end of preset time Touch timer s sensor ON OFF D By pressing the extreme lower position of...

Страница 29: ...atic cooking mode off anytime by bringing power setting to 0 Power setting 1 2 3 4 5 6 7 8 Max power 40 1 12 2 2 56 4 16 7 12 2 3 12 Safety switch off Power setting 1 2 3 4 5 6 7 8 9 Hours lapse prior...

Страница 30: ...ter signals to select segment or relay triggering incorrect Contact authorized center for technical assistance specifying the error code Er42 5V at the controller outside the valid range or too much v...

Страница 31: ...ow Never use any aggressive sprays or limestone removers Fig 3 Major stains are removed with special ceramic glass cleansers Follow strictly the manufacturer s instructions Be careful to remove any re...

Страница 32: ...32 El fabricante implementa mejoras continuamente Por esta raz n el texto y las ilustraciones de este manual pueden variar sin aviso previo...

Страница 33: ...tilizarlo Como abarcan diferentes tipos o modelos algunas caracter sticas podr an no aplicarse a su aparato en particular Instrucciones de conexi n La conexi n debe realizarse siguiendo las instruccio...

Страница 34: ...a o agrietada En caso de defectos desconectar inmediatamente la alimentaci n el ctrica En caso de interferencias desconectar el cable de alimentaci n el ctrica y llamar al Servicio de Asistencia El ap...

Страница 35: ...mm B 465 mm C 740 mm D 455 mm E 45 mm F 10 mm G 50 mm H 1 6 mm La placa de cocci n se puede empotrar s lo en una encimera de 25 a 40mm de espesor El elemento inferior de la cocina no debe tener caj n...

Страница 36: ...na separaci n entre los contactos que interrumpa el suministro en caso de sobretensi n de categor a III Para garantizar la seguridad en caso de incendio los aparatos de este tipo s lo se pueden empotr...

Страница 37: ...n la superficie de vitrocer mica No limpiar la superficie de vitrocer mica a n caliente con productos qu micos podr a da arse Ollas adecuadas para la placa de cocci n por inducci n Las zonas de cocci...

Страница 38: ...tidades de alimentos 3 Cocci n lenta continuaci n de la cocci n despu s del calentamiento fuerte 4 5 Cocci n lenta de grandes cantidades 6 Cocci n para asar o dorar alimentos 7 8 Cocci n para asar ali...

Страница 39: ...Semivalor Valor m ximo Gesti n de la placa de cocci n En el momento del encendido de la placa de cocci n en vitrocer mica se encienden todos los indicadores un instante La placa de cocci n est lista...

Страница 40: ...rm 42 C Pulsar el sensor F El led que hay sobre la tecla parpadea En 5 segundos pulsar el cursor de la zona de cocci n elegida En la pantalla de la zona de cocci n aparece la indicaci n u Activaci n d...

Страница 41: ...a una olla que contiene alimentos calientes sobre la zona de cocci n Atenci n peligro de quemaduras Programaci n de cocci n particularmente potente zona de cocci n con s mbolo P Para una cocci n r pid...

Страница 42: ...ivados El resto de LEDS timer multi circuito etc permanecen encendidos seg n el estado de la funci n asociada La funci n pausa puede permanecer activada hasta 10 minutos como m ximo Si la pausa contin...

Страница 43: ...iempo residual y el led de la zona correspondiente parpadea Si el menor tiempo residual corresponde al del avisador los leds no parpadean Para conocer el tiempo residual de otras zonas en las que el t...

Страница 44: ...ener pulsado el cursor E de la zona de cocci n elegida durante al menos 3 segundos para ver la indicaci n A de activaci n del sistema de cocci n autom tico El nivel de cocci n pulsado ser el nivel de...

Страница 45: ...est mal conectado o es defectuoso Defecto de la unidad de potencia Contactar con el centro de asistencia t cnica autorizado y especificar el c digo de error Er36 Corto circuito en el sensor de tempera...

Страница 46: ...ien la olla Fig 3 Las manchas de agua se pueden eliminar con una soluci n de vinagre pero sin pasar sobre el marco de algunos modelos para no quitarle el brillo No utilizar detergentes o sprays agresi...

Страница 47: ...LIB30446...

Отзывы: