Minimum Installation Clearances
The measurements to combustible materials are
for advice only. In all installations surrounding
inflammable materials must not exceed 80°C and
therefore in certain circumstances they may need
to be increased.
The stove must always stand perfectly level and
have sufficient space allowed for commissioning
the stove and service work. This may lead to the
clearances to non-inflammable materials also
being increased from those in the tables below.
* The stove is supplied with a cast iron
hearth plate, which we strongly recommend
that you use to protect the surface below. It
is also the minimum non-inflammable
thickness required for installation.
⧫
This is the minimum distance in front, at
floor level, from the base of the stove. All
combustible materials above floor level in
front of the appliance must be a minimum
distance of 500mm away or any
combustible materials must not exceed
80°C.
Belfort
Minimum clearance
from combustible
materials
Minimum clearance
from non-inflammable
materials
A
450mm
300mm
B
200mm
150mm
C
225mm
⧫
225mm
D
200mm
150mm
E
200mm
150mm
F
12mm*
12mm*
Savoy
Minimum clearance
from combustible
materials
Minimum clearance
from non-inflammable
materials
A
450mm
300mm
B
200mm
150mm
C
225mm
⧫
225mm
D
200mm
150mm
E
200mm
150mm
F
12mm*
12mm*
Burgundy/
Bourgogne
Minimum clearance
from combustible
materials
Minimum clearance
from non-inflammable
materials
A
450mm
300mm
B
300mm
150mm
C
225mm
⧫
225mm
D
300mm
150mm
E
300mm
150mm
F
12mm*
12mm*
F
C
A
E
B
D