background image

Ideal Installation  

 
 

Ideal Installation 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Flue Terminations 

Chimney cowls 

The chimney cowl is an important part of the installation and can be often ignored.  
A cowl normally serves more than one purpose.  
 

1)

 

It  prevents  rain  entering  the  chimney  system  which  will  result  in  poor  chimney  operation  and  potential 
damage to the appliance. 

2)

 

It can prevent birds nesting resulting in partial or blocked chimneys.  

3)

 

Most important it can act as a stabilizer in windy conditions.  
 

Different  types  of  cowls  produce  different  conditions  which  will  affect  the  negative  pressure  within  the  chimney 
system. Great caution must be taken when choosing the cowl as an incorrect choice can result in poor stove operation. 
Some anti down draught cowls work by inducing up draught which  can seriously affect the combustion within the 
burner and may even cause damage to the catalyser. 
 
It is as important to fit the cowl correctly to the flue termination. All installations of this type should have a chimney 
pot fitted to the top of the chimney. The flue liner should be brought to the top of the chimney pot with insulation 
between the liner and pot. 

Minimum of 4m  
total flue height 

Cowl to prevent 
ingress of rain, birds 
and/or to assist with 
flue stabilization 

Flue liner support collar 

Weatherproof chimney capping and pot 

Sound chimney brick work 

Stainless steel liner 

Flexible to single wall adapter 

Register plate preventing the escape of 
heat, positioned as low as practicable to 
aid convection 

Access for cleaning 

Sufficient clearance behind 
stove for maintenance 

Hearth plate laid on level and stable 
supporting hearth 

Содержание Burgundy

Страница 1: ...TECHNICAL ABGO 1 SIDINGS CLOSE WEDNESFIELD ROAD WOLVERHAMPTON WV11 3DR Oil Stove Installation INSTRUCTIONS FOR FRANCO BELGE OIL STOVES...

Страница 2: ...e publications may be superseded during the life of this manual BS 799 Part Five Specification for Oil Tanks BS 5410 Part One Oil Firing Installations Up To 44kW BS 4543 Parts One Three Factory Made I...

Страница 3: ...d Installation Commissioning and Servicing Technicians and Tank Installation Technicians from the need to give notice and pay a fee when carrying out new installation work replacement work or making a...

Страница 4: ...ote acting fire valves and major changes to flueing systems Part L1 of the Regulations which came into force at the same time covers the energy efficiency aspects of heating system installation partic...

Страница 5: ...plate 5 and the clamp 4 from the back and refit them on the top with the 2 screws and washers supplied 7 ensuring there is a good seal 2 Set the ceramic rope in the groove and fix the flue collar at r...

Страница 6: ...the requirements of Building Regulations and providing suitable access to facilitate servicing the stove providing a setting which will complement the stove is not a luxury it is the practicality of m...

Страница 7: ...ss required for installation This is the minimum distance in front at floor level from the base of the stove All combustible materials above floor level in front of the appliance must be a minimum dis...

Страница 8: ...f this heat by being constructed with an internal surface as smooth as possible and by being thermally insulated Both these requirements can be met in an existing chimney by lining it with a stainless...

Страница 9: ...ue shall have no more than four bends each providing a maximum change of direction of 45 there should be not more than two of these bends before an access point for sweeping and two between a sweeping...

Страница 10: ...e anti down draught cowls work by inducing up draught which can seriously affect the combustion within the burner and may even cause damage to the catalyser It is as important to fit the cowl correctl...

Страница 11: ...A metal bowl oil filter mounted to allow adequate room for the removal of the sediment bowl and filter element without difficulty should be fitted in the pipeline to the property We recommend a repla...

Страница 12: ...in its main body it regulates with a float valve the depth of oil held it meters with an adjustable outlet the fuel supplied to the burner and its safety float valve will isolate the fuel should the l...

Страница 13: ...Toby valve CI valve...

Страница 14: ...ill give the actual pressure within the stove but it is not possible to verify the pressures to enable the correct adjustment of the draught stabilizer without a suitable manometer The pressure must b...

Страница 15: ...Draught Requirements Burgundy 0 075inches WG 17 Pa 0 035 inches WG 8 Pa Note This is not a water gauge used to measure gas pressure Minimum Maximum Inches water gauge...

Страница 16: ...ions The customers who will operate the stove are an essential component of any installation Ensuring they understand the operation of the stove its controls and what to expect from the installation w...

Страница 17: ...e stove and flue warm the supply of air being induced into the burner will increase and it will be possible to raise the stove s firing rate progressively until the stove is running at its maximum out...

Страница 18: ...inutes should be allowed for the flue draft to stabilise after adjusting the flue stabilizer Low Fire Minimum flame size Flue draught set at the requirement for low fire No 1 setting e g 0 04 wg The c...

Страница 19: ...ases of draught from external conditions such as wind If this is the case the flue termination position must be examined to confirm it is correct and a draught stabilising cowl fitted 2 Excessive nega...

Страница 20: ...Advise the customer that if the stove is to be out of operation for more than a few weeks that the isolation tap which should be located by the stove should be turned off demonstrate this to the custo...

Страница 21: ...Fault Finding Flow Charts...

Страница 22: ...Check continuity of igniter Replace igniter if defective Is igniter 2mm from burner floor Adjust igniter to 2mm above burner floor Has oil reached area below igniter...

Страница 23: ...Dwyer 460 flue draught gauge recommended Flame burning only from inlet port...

Страница 24: ...Fit a stabilizing cowl and or Secondary draught stabilizer Fit a secondary draught stabilizer Adjust draught stabilizer Direct heat from heater or hair drier into stove Balance draught stabilizer agai...

Страница 25: ......

Страница 26: ...n good condition replace if damaged or hard 13 Using a vacuum cleaner remove dust dog and cat hairs and any cobwebs from behind the stove that could be a fire hazard 14 Reassemble the stove and light...

Страница 27: ...Service Record Year Date Company Engineer Tel No Parts replaced 1 2 3 4 5 6 7 8 9 10...

Страница 28: ...ppliances without prior notice We make every effort to ensure that the information provided in this document is correct and accurate at the time of printing We would request that you inform ABGO of in...

Отзывы: