background image

1.

Product information

1.1. Package

• 1 package : Stove complete. The ceramic coals are
supplied inside the combustion chamber.

1.2. General characteristics

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 05 04 . . . . . 154 05 05

GAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Natural gas . . . . Propane

Type/category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G20 / I2H . . . . . G31 / I3P

Gross calorific value (heat inpout)

. . . . . . . . . . . . . . kW

. . . . . . . . . 4.3

. . . . . . . . 4.2

Nominal output . . . . . . . . . . . . . . . . . . . . . . . . . kW

. . . . . . . . . 3 . . . . . . . .

2,75

Supply pressure . . . . . . . . . . . . . . . . . . . . . . . mbar

. . . . . . . . . 20 . . . . . . . . . 37

Burner pressure . . . . . . . . . . . . . . . . . . . . . . . mbar

. . . . . . . .

18.5 . . . . . . .

36.5

Gas rate

. . . . . . . . . . . . . . . . . . . . . . . . . . . m

3

/h

. . . . . . . .

0.44 . . . . . . .

0.16

Injector size

. . . . . . . . . . . . . . . . . . . . . . . . . bray

. . . . . . .

18 / 280 . . . . . 18 / 280

T.T.B.. Cut off temperature . . . . . . . . . . . . . . . . . . °C

. . . . . . . . . 90 . . . . . . . . . 90

Reset temperature . . . . . . . . . . . . . . . . . . . . . . . °C

. . . . . . . . . 75 . . . . . . . . . 75

1.3. Description

The Belfort stove has been individually designed to add
traditional charm and character to your home. Providing a
highly efficient heat source, the Belfort has the look and
charm of a ‘real’ stove coupled with the convenience of
clean burning gas.
The stove is designed to run both off natural or LPG gas
however each individual appliance is only capable of run-
ning off the type of gas specified at the time of purchase.
It is important to note that once a type of gas has been
specified the stove cannot run off any other type. The type
of gas which your stove is capable of burning is stated on
the data information panel (See Paragraph 3).

1.4. Principle of operation

THERMOSTATIC SWITCH (TTB) : The TTB is a normally
closed bi-metallic switch which is designed to open at a
pre-set temperature (90C) and reset to the closed position
when the temperature falls to a reset level (normally 15 C
below the operating temperature).

The system is not adjustable, and should not be rendered
inoperative.

If parts of the system require replacement only original
parts must be used.

2.

Installation instructions

These instructions have been compiled in accordance with
BS 5258 Part 12: 1986.

It is required by law that any appliance using natural or
LPG gas is installed by a competent person (e.g. CORGI
registered), in conjunction with the these instructions and
the requirements as laid down in the following Regulations
and British Standards:
- The Gas safety (Installation and Use) Regulations 1994.
- The Building Regulations (issued by the department of
the Environment).
- The Building Standards (Scotland) (Consolidation) Regu-
lations.

APPLIANCE TO BE INSTALLED ACCORDING TO NA-
TIONAL REGULATIONS.

The Belfort is a gas stove designed to run on either natural
gas or LPG. The burner units are not interchangeable
between the two types of gas.

The stove is a radiant convector fuel effect stove. The
Belfort can be placed directly inside any fireplace opening
of the dimensions noted within the installation instructions.

Ensure that the stove corresponds to the type of gas it is
to be used with. This can be confirmed by checking the
data badge located on the rear face of the appliance.

Prior to installation it is essential that the chimney should
be swept and its condition and suitability for use with the
appliance checked.

All surfaces except the control knob are considered to be
working surfaces.

2.1. Siting the appliance

The gas supply connection to the appliance is at the rear
right hand side. The connection requires 8 mm diameter
semi-rigid pipe, not more than 1 metre in length.

The appliance can be installed in any adequate area suita-
ble for solid fuel fires and stoves.

The flue pipe required is either a single or double walled
pipe of 126 mm (5”) diameter.

If the appliance has to be located in an opening, there must
be at least a clearance of 50 mm at the left hand side of the
appliance, 50 mm at the back of the appliance, 150 mm at
the right hand side of the appliance and 50 mm above from

Document 897-1 ~ 22/08/1997

Belfort

poêles gaz / gas stove

Réf. 154 05 04 / 154 05 05

10

Notice de référence

Содержание 154 05 04

Страница 1: ...anco Belges F 59660 MERVILLE T l phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Mat riel sujet modifications sans pr avis Document non contractuel Belfort Po le gaz de chemin e conve...

Страница 2: ...arbon 1 Fond de la chambre de combustion 2 Br leur 3 Support de la matrice en c ramique 4 Matrice en c ramique 5 Trous du br leur 6 Bloc veilleuse Fig 6 Mise en place des charbons m dians et des charb...

Страница 3: ...e ceramic matrix 1 Back wall of the combustion chamber 2 Burner 3 Matrix Support 4 Matrix ceramic 5 Burner holes 6 Pilot Fig 6 Fitting the medium ceramic coals and the upper ones Fig 7 Control knob an...

Страница 4: ...hydrocarbures liqu fi s situ es l int rieur des b ti ments d habitation et de leurs d pendances Norme NF P 45 204 Installations de gaz DTU 61 1 R glement Sanitaire D partemental Type RDS Fran ais Somm...

Страница 5: ...La diffusion de la chaleur s effectue la fois par rayonnement au travers de la vitre et tout autour du foyer Le fonctionnement de la veilleuse est permanent La vanne gaz comporte un dispositif de s c...

Страница 6: ...rage Si la chemin e a des tendances aux refoulements cause de sa situation par rapport des obstacles voisins il faut coiffer la sortie d un anti refouleur ou d un aspirateur statique ou rehausser la c...

Страница 7: ...l allumeur pi zo V rifier si l isolant de la bougie n est pas fissur remplacer la bougie si n cessaire Thermocouple A la mise en service de l appareil la flamme de la veilleuse s teint lorsque l on to...

Страница 8: ...pel votre installateur chauffagiste 3 5 Recommandations A chaque allumage v rifier que la longueur de la flamme de la veilleuse reste suffisante 2 3 cm pour allumer rapidement le br leur Trop de retar...

Страница 9: ...11 Connecting the gas supply p 11 Pressure testing p 11 Coals layout p 11 Test for spillage p 11 Service section p 12 User instructions p 12 Important Notes p 12 Data information p 12 Arranging the la...

Страница 10: ...w that any appliance using natural or LPG gas is installed by a competent person e g CORGI registered in conjunction with the these instructions and the requirements as laid down in the following Regu...

Страница 11: ...aling rope in the groove on the rear and fit the flue spigot using the three bolts and washers supplied ensuring there is a good seal 2 3 Ventilation G B Only The Belfort has no requirement for additi...

Страница 12: ...the type of gas it is to be used with This can be confirmed by checking the data badge located on the rear face of the appliance Remember at all times this product is concerned with high temperatures...

Страница 13: ...approximately 10 minutes for the switch to automatically reset Re light the stove in accordance with section 5 Operating the stove On repeated operation of the thermostatic switch the stove should be...

Страница 14: ...mic rope 15x2 A B 1 63 m 20 181614 Tresse de c ramique Ceramic rope d 9 5 mm A B 1 42 m 21 181615 Tresse de c ramique Ceramic rope 12 A B 1 35 m 22 188315 Veilleuse Pilot 0 2 A 01 22 188316 Veilleuse...

Страница 15: ...18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 36 37 38 39 40 41 42 43 44 45 46 48 49 50 4 4 16 19 19 20 53 53 11 47 51 52 Figure 8 Document 897 1 22 08 1997 R f 154 05 04 154 05 05 po les gaz gas...

Страница 16: ...ranty certificate Legal warranty Our products are guaranteed for twelve months against any defect flaw or imperfection During this time all parts judged defective by our Warranty control department ma...

Отзывы: