1.
Product information
1.1. Package
• 1 package : Stove complete. The ceramic coals are
supplied inside the combustion chamber.
1.2. General characteristics
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 05 04 . . . . . 154 05 05
GAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Natural gas . . . . Propane
Type/category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G20 / I2H . . . . . G31 / I3P
Gross calorific value (heat inpout)
. . . . . . . . . . . . . . kW
. . . . . . . . . 4.3
. . . . . . . . 4.2
Nominal output . . . . . . . . . . . . . . . . . . . . . . . . . kW
. . . . . . . . . 3 . . . . . . . .
2,75
Supply pressure . . . . . . . . . . . . . . . . . . . . . . . mbar
. . . . . . . . . 20 . . . . . . . . . 37
Burner pressure . . . . . . . . . . . . . . . . . . . . . . . mbar
. . . . . . . .
18.5 . . . . . . .
36.5
Gas rate
. . . . . . . . . . . . . . . . . . . . . . . . . . . m
3
/h
. . . . . . . .
0.44 . . . . . . .
0.16
Injector size
. . . . . . . . . . . . . . . . . . . . . . . . . bray
. . . . . . .
18 / 280 . . . . . 18 / 280
T.T.B.. Cut off temperature . . . . . . . . . . . . . . . . . . °C
. . . . . . . . . 90 . . . . . . . . . 90
Reset temperature . . . . . . . . . . . . . . . . . . . . . . . °C
. . . . . . . . . 75 . . . . . . . . . 75
1.3. Description
The Belfort stove has been individually designed to add
traditional charm and character to your home. Providing a
highly efficient heat source, the Belfort has the look and
charm of a ‘real’ stove coupled with the convenience of
clean burning gas.
The stove is designed to run both off natural or LPG gas
however each individual appliance is only capable of run-
ning off the type of gas specified at the time of purchase.
It is important to note that once a type of gas has been
specified the stove cannot run off any other type. The type
of gas which your stove is capable of burning is stated on
the data information panel (See Paragraph 3).
1.4. Principle of operation
THERMOSTATIC SWITCH (TTB) : The TTB is a normally
closed bi-metallic switch which is designed to open at a
pre-set temperature (90C) and reset to the closed position
when the temperature falls to a reset level (normally 15 C
below the operating temperature).
The system is not adjustable, and should not be rendered
inoperative.
If parts of the system require replacement only original
parts must be used.
2.
Installation instructions
These instructions have been compiled in accordance with
BS 5258 Part 12: 1986.
It is required by law that any appliance using natural or
LPG gas is installed by a competent person (e.g. CORGI
registered), in conjunction with the these instructions and
the requirements as laid down in the following Regulations
and British Standards:
- The Gas safety (Installation and Use) Regulations 1994.
- The Building Regulations (issued by the department of
the Environment).
- The Building Standards (Scotland) (Consolidation) Regu-
lations.
APPLIANCE TO BE INSTALLED ACCORDING TO NA-
TIONAL REGULATIONS.
The Belfort is a gas stove designed to run on either natural
gas or LPG. The burner units are not interchangeable
between the two types of gas.
The stove is a radiant convector fuel effect stove. The
Belfort can be placed directly inside any fireplace opening
of the dimensions noted within the installation instructions.
Ensure that the stove corresponds to the type of gas it is
to be used with. This can be confirmed by checking the
data badge located on the rear face of the appliance.
Prior to installation it is essential that the chimney should
be swept and its condition and suitability for use with the
appliance checked.
All surfaces except the control knob are considered to be
working surfaces.
2.1. Siting the appliance
The gas supply connection to the appliance is at the rear
right hand side. The connection requires 8 mm diameter
semi-rigid pipe, not more than 1 metre in length.
The appliance can be installed in any adequate area suita-
ble for solid fuel fires and stoves.
The flue pipe required is either a single or double walled
pipe of 126 mm (5”) diameter.
If the appliance has to be located in an opening, there must
be at least a clearance of 50 mm at the left hand side of the
appliance, 50 mm at the back of the appliance, 150 mm at
the right hand side of the appliance and 50 mm above from
Document 897-1 ~ 22/08/1997
Belfort
poêles gaz / gas stove
Réf. 154 05 04 / 154 05 05
10