2 - Safety Precautions
The following instructions must be adhered to, in order to ensure a safe working environment and
the safety of the user.
Note: When unpacking or manoeuvring the searchlight into its fixing position, suitable
lifting points must be used in order to prevent damage to the equipment or personal injury.
Because of the high internal pressure within the lamp, there is a risk of explosion in either a hot
or cold state;
During operation this lamp emits intense UV radiation which is harmful to the eyes and skin.
Suitable protection should be worn;
The high luminance of the arc can cause severe damage to the eye if viewed directly.
ALWAYS wear suitable protective goggles when viewing the lamp;
Always use protective sleeves supplied with the lamp;
Should it be necessary to examine the lamp with the front bezel removed, always use a
protective shield and wear goggles to ensure a safe working environment;
Searchlights get hot. Never touch the unit when lit and always allow 15 to 20 minutes for
cooling down after turning the searchlight off;
Never place anything on or cover the searchlight when in use;
Ensure the lamp has cooled sufficiently before removal;
If undue force appears necessary to remove the lamp, the equipment should be inspected by a
competent person or contact the manufacturer;
When disposing of lamps, return the lamp, via the supplier, to the lamp manufacturer in its
complete packaging;
Due to the vast range of lamps available it may appear possible that more powerful lamps can
be used in the equipment than for which it was designed. Even when the unit will physically
accept a higher wattage or voltage lamp, this substitution is not recommended and is
dangerous. This action will also void any warranties on the equipment.
Always refer to the lamp manufacturers technical data when dealing with lamps.